Settings/Service
157
No: Text
Selection option/ default
Description
127: Autoclean level
selection
Display all cleaning levels
Only display Level 1
Only display Level 2
Only display Level 3
Only display Level 4
Default: Display all cleaning
levels.
The user has the option to select
the display of the cleaning levels
under 5 selection options.
Display all cleaning levels: all
cleaning levels are available.
Only display Level 1: only
cleaning level 1 is available.
Only display Level 2: only
cleaning level 2 is available.
Only display Level 3: only
cleaning level 3 is available.
Only display Level 4: only
cleaning level 4 is available.
122: DirectMode ID
length
4 characters to
8 characters
Default: 5
The user can save an ID to a
program and use that specified
ID to access this program. This
parameter indicates how many
digits this ID may have.
125: Core temp delay
duration
From 1 s to 300 s
Default: 30 s
This parameter defines after how
many seconds from the program
start the core temperature is
measured, to avoid incorrect
measurement at the thigh
temperature of the core
temperature sensor.
126: Scanner Activated
Activate/deactivate with
toggle button
Default: Deactivated
The user can activate the
Barcode scanner to call up
cooking programs by scanning
the barcode.
131: Hide program list
menu
Activate/deactivate with
toggle button
Default: Deactivated
The menu groups and search
field can be hidden in the
program list.
132: Disable step
overview for
QuickMode
Activate/deactivate with
toggle button
Default: Deactivated
In QuickMode, the step overview
field can be hidden in the
program list.