Settings/Service
154
No: Text
Selection option/ default
Description
55: Keep warm sound
EndCombiProgram
EndProgram
EndStep
KeepWarm
ReachPreheat
StartCombiProgram
Default: ReachPreheat
This tone sounds at the
beginning of the holding process
of the special program
Cook & Hold.
56: Keep warm volume
From volume level 0 to
volume level 10.
Default: 5
The volume of the tone that
sounds at the beginning of the
holding process of the special
program Cook & Hold can be
adjusted.
57: Keep warm
duration
From 0 s to 999 s
Default: 3 s
The playback time of the tone is
adjustable.
58: Keep warm repeat
after
From 0 s to 999 s
Default: 3 s
The tone can be repeated after a
certain time. This time can be
set.
60: Gas fault volume
from volume level 1 to
volume level 10
Default: 10
If the device cannot ignite the
gas burner, the device is
switched off and a fault is
displayed. This is where the
volume of the alarm can be set.
61: Critical alarm
volume
From volume level 1 to
volume level 10.
Default: 10
When an error occurs that shuts
down the device a tone sounds.
The volume of this tone can be
adjusted.
62: Daylight Saving
Time
Activate/deactivate with
toggle button
Default: Activated
The Daylight Saving Time takes
place automatically when this
parameter is activated.
63: DST rule
Europe
USA
Australia
New Zealand
Israel
Chile
Custom
Default: Europe
If the parameter 62 is activated,
the user can change the daylight
Saving Time according to a rule.
When the user dials the custom
rule, additional settings are
displayed in menu item 23 to
customise the time changeover.
Содержание GENIUS MT
Страница 169: ...Appendix 169 Ende der Liste für Textmar ke Inhalt4 ...
Страница 170: ...Appendix 170 ...
Страница 171: ...Appendix 171 ...