Settings/Service
158
No: Text
Selection option/ default
Description
133: Preheating mode
for program list
Full PreHeating adjustment
Fixed on "no Preheating"
Fixed on "Preheating"
Default: Full PreHeating
adjustment
The user can select a standard
for preheating for the programs.
Full PreHeating adjustment: free
setting of preheating before
starting the program, no
standard is defined.
Fixed on "no Preheating":
Preheating is not activated.
Fixed on "Preheating":
Preheating is always enabled
before starting the program.
134: Disable icon
Multi Cooking during
operation
Activate/deactivate with
toggle button
Default: Deactivated
The Multi Cooking field can be
hidden during operation.
135: Disable steamshot
Activate/deactivate with
toggle button
Default: Deactivated
The manual steaming field can
be hidden during operation.
136: Cooking add time
only at the end
Activate/deactivate with
toggle button
Default: Deactivated
For multi step cooking/baking
programs, the time extension
field can only be activated in the
final step.
Activated: Only in the last step.
Deactivated: Cooking time
extension possible in every step.
137: Disable core
temperature
monitoring during
cooking
Activate/deactivate with
toggle button
Default: Deactivated
After the program starts, the
user can select the core
temperature field to display the
current core temperature. This
parameter activates/deactivates
this function.
144: Break pulsing
temperature
difference
From 1 °C to 100 °C
Default: 5 °C
This parameter indicates how
much °C the temperature may
drop during the pulsing until the
fan switches back on.
145: Repeat Mode
Activate/deactivate with
toggle button
Default: Deactivated
When activating this parameter,
the restart field is displayed at
the end of a cooking/baking
process to be able to restart the
previous operation.
Содержание GENIUS MT
Страница 169: ...Appendix 169 Ende der Liste für Textmar ke Inhalt4 ...
Страница 170: ...Appendix 170 ...