MP500/4N-8-16 Installation
59
5.4.4 Battery compartment and fastening points for the optional features in the MP500/16 control panel
Figure 29 - Fastening points for optional features in the MP500/16 control panel
Expansion
A
Fastening points for EP508 or Web server expansion
B
Fastening points for EP508 expansion
C
Fastening points for EP508 expansion
D
Fastening points for EP508 expansion
E
Compartment for GSM 2 antenna
F
Compartment for back-up battery
5.4.5 Assembling expansion modules in the MP500/16 control panel
IMPORTANT!
The connection and disconnection of the optionals and accessories must always be done while the control
panel is disconnected from all power supplies (both mains and battery).
Figure 30 - Available positions for expansion in the MP500/16 control panel
Inside the MP500/16 control panel, 4 EP508 expansions (positions
A
,
B
,
C
, and
D
) can be assembled. The expansions must be
fastened with the self-tapping screws supplied.
The positions
A
and
B
can be accessed by releasing and turning the mother board. If the GSM transmitter is used, it is not possible to
use position
B
.
Position
A
is dedicated to the IT500WEB interface, but in its place an EP508 board can be installed.
IMPORTANT!
It is advisable to NOT INSTALL the radio expansion module in the MP500/16 control panel, because the
metallic container of the control panel reduces reception of the radio signals, obstructing control of the radio devices
associated with it.
A
B
C
D