104
MP500/4N-8-16 Installation
To delete the address of the KP500DP/N or KP500D/ST keypad, follow the instructions below:
1. Open the tamper contact (release the keypad from the relative bracket - see
Figure 49 - Removal of the KP500DP/N - KP500D/ST
2. Press the
F4
key for at least 5 seconds. This will appear on the display:
3. Press
F1
to confirm or
F4
to cancel.
In reference to the radio expansion reset, it is also necessary to reacquire all the radio devices associated with it.
IMPORTANT!
Following the Reset command of the radio expansion, it is necessary to carry out the local reset of all the radio
sirens of the system, and then reacquire them.
7.10
REPLACING THE BATTERY
When a battery can no longer maintain its charge, it must be replaced with a similar one in order not to compromise the correct
functioning of the system.
To replace the battery, follow the instructions below:
1. Activate the Maintenance status (see paragraph
) and open the device containing the battery.
2. Disconnect the old battery and remove it.
3. Insert the new battery and connect it with the special connectors, matching the polarity.
4. Close the device.
5. Carry out a Test battery check (see the
Programming Manual
).
IMPORTANT!
The battery may only be replaced by trained and qualified personnel.
DIRECTIVE 2012/19/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 4 July 2012 on waste
electrical and electronic equipment (WEEE)
The symbol of the crossed-out wheeled bin on the product or on its packaging indicates that this product must not be
disposed of with your other household waste.
Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the
recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at
the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human
health and the environment. For more information about where you can drop off your waste equipment for recycling, please
contact your local city office, your household waste disposal service or the shop where you purchased the product.
7.11
TURNING OFF THE ENTIRE SYSTEM
Whenever the entire system must be turned off, follow the instructions below:
1. Activate Maintenance status (see paragraph
) and open the control panel.
2. Disconnect the mains power supply.
3. Disconnect the battery.
4. If supplemental power supply units are present, disconnect them in the same sequence (points 2 and 3).
Before restoring power, wait at least 1 minute.
IMPORTANT!
It is fundamental to put the control panel in Maintenance status before turning it off.
Failure to follow these instructions may cause a loss of data and compromise the correct functioning of the system.