MP500/4N-8-16 Installation
111
Pollution degree
Grade 2
Overvoltage Category
CAT II
Degree of protection of casing
IP40/ IK06
Dimensions (W x H x D)
435 x 320 x 93 mm
Weight (without battery)
5600 g
For further information, see also paragraph
Note 1)
If the battery is not connected to the terminals of the connection cables, (red and black Faston) there is no power.
Note 2):
remotely assisted system with guaranteed intervention in case of lack of power
;
Note 3)
in case of blackout, the
+SR
does not supply voltage.
8.4
KEYPAD DISPLAY KP500D/N - KP500DV/N
Nominal power voltage
13.8 V
⎓
(taken from bus)
Keypad operating voltage
9 V
⎓
to 15 V
⎓
Nominal current absorbed at 12 V
⎓
20 mA (in stand-by, only LED for presence mains supply)
32 mA (operative, with level 1 backlighting)
120 mA (operative, with level 4 backlighting)
200 mA max. (in message listening
– version DV/N)
Nominal voltage on +V outputs
13.8 V
⎓
Max current deliverable on +V outputs
100 mA
Max total length of control panel-peripheral serial Bus line
400 m
Max length of the audio line (audio bus)
300 m with twin telephone line
Max length of the connection between each sensor and the
keypad
500 m
Max length of the connection between a fast sensor (roller, shock,
...) and the keypad.
100 m
Type of communication
Elkron serial protocol
Tamperproof switch
standard with clear channel signalling in the control panel
Auxiliary inputs (only KP500D/N)
2
Protection against inserting false codes
Yes
Certified operating temperature
(EN50131
– Environmental class II, internal general)
-10°C to +40°C
Average relative humidity during operation
75%
Storage temperature
-20°C to +60°C
Degree of protection of casing
IP40 / IK06
Weight
250 g
Dimensions (W x H x D)
151 x 125 x 29 mm
8.5
KEYPAD TOUCH SCREEN KP500DP/N
Nominal power voltage
13.8 V
⎓
(taken from bus)
Keypad operating voltage
10 V
⎓
to 15 V
⎓
Nominal current absorbed at 12 V
⎓
32 mA (in stand-by, only LED for presence mains supply)
68 mA (average absorption with backlighting at level 1)
110 mA (average absorption with backlighting at level 4)
200 mA (maximum peak absorption)
Max total length of control panel-peripheral serial Bus line
400 m
Type of communication
Elkron serial protocol
Type of memory for program maintenance
Data Flash
Type of memory for vocabulary maintenance
Data Flash
Certified operating temperature
(EN50131
– Environmental class II, internal general)
-10°C to +40°C
Average relative humidity during operation
75%
Storage temperature
-20°C to +60°C
Degree of protection of casing
IP40 / IK06
Weight
460 g
Dimensions (W x H x D)
160 x 130 x 23.5 mm