MP500/4N-8-16 Installation
13
1 - THE MP500/4N-MP500/8-MP500/16 SYSTEMS
This chapter illustrates the MP500/4N, MP500/8, and MP500/16 systems. More specifically, the following are analysed:
the main characteristics of the systems;
the system architecture and the maximum dimension possible;
the connectivity of systems towards to outside;
the various devices and accessories that make up the systems.
1.1
MAIN CHARACTERISTICS
The MP500/xx wired intrusion alarm systems are modular, suitable for small - mid-sized systems in residential, industrial, and service
settings.
The components and main functions of the system are certified Grade 3, according to EN50131 standards.
Keypads, readers and expansions are connected to the control panel microprocessor by a proprietary field bus.
Detectors, sirens, and other signals are instead connected to the inputs and outputs present in the control panels and in other devices
connected to the bus.
All the inputs can be configured for both type and specialisation.
The remote alarm notifications can be made with vocal message, text message, or numerical protocol (for the connection to alarm
reception units).
The system can be managed locally and remotely by means of a land line, cell phone, text message, and Internet.
Other functions available are:
Programming via PC
equipped with Hi-Connect software (3.50 or higher).
Saving of the program on a USB pen drive
to transfer the program between PCs and control panel or save a back-up copy.
Firmware device updates
via USB interface with a pen drive
Technological signalling
, that are activated by an event other than intrusion. Following an event of this type, the system can
command even specific actuations.
Advanced vocal alarm calls
, that allow specific alarm messages to be sent for individual partitions and/or inputs.
Vocal message diffusion
, system armed, system disarmed, system diagnostic information can be communicated to user via
hands-free vocal messages diffused by vocal keypad.
Service vocal message
, the user may use any vocal keypad to issue a memo that will be reproduced locally until the subsequent
deactivation, by any vocal keypad.
Remote ambient listening function
, enables the user to hear, via telephone, to what is happening in the environment, by
addressing up to 8 listening points through the vocal keypads.
Vocal help for remote management
, used by the system to guide the user with vocal messages.
Door opener
, the electric lock can be controlled via the customized output, limiting access to specific areas only to authorised
personnel. Date, time and user who have commanded the opening are recorded in the control panel.
Telephonic activation of an output without a connection charge
. By taking advantage of the GSM telephone number
recognition by the control panel, it is possible to generate a command on the specific output and close communications after the
first 3-4 rings without charging for the call.
Advanced automation
. Through the timing programmer built into the control panel, it is possible to arrange a series of automatic
and repetitive commands weekly.
Moreover, there are two auxiliary functions that are not in conformity with current laws that allow the guaranteed security of the system
to be increased easily and economically, without however replacing the dedicated systems:
Emergency response signal
, which generates service signals when a dedicated button is activated or no movement is detected
in the controlled environment.
Fire alarm
, which generates service signals from part of the control panel when fire detectors managed by the same are installed.
ATTENTION!
If the “emergency response call” is required, it is necessary to have a remote emergency response system in
conformity with current legislation on this topic.
To create a system that fully meets all the requirements of a fire detection system, consult Elkron's general catalogue in the
Fire Prevention section.