5.10 INSTALLING THE READER
The electronic key readers and transponders are installed in boxes to be built-in or wall-mounted and positioned in a dry area.
The reader is suitable to be installed on BTicino Magic frame and using BTicino code A5374/1 adapters, on BTicino TT Matix frames.
Moreover, by using the adaptor frames (not provided), the readers can be inserted as switches within the wiring, like the B-ticino® Light
/ International / Living ; Gewiss® Playbus ; AVE® Sistema 45 ; Axolute® ; Eikon® ; Vimar® Idea ; Vimar® Plana; Vimar 8000 ; Simon
Urmet nea, etc.
IMPORTANT!
In accordance with EN50131 standards, the readers installed outside the protected zone must be protected by
devices to prevent tampering.
IMPORTANT!
The absence of the tamper results in the loss of EN50131 certification.
The readers are equipped with two freely programmable auxiliary inputs referring to positive.
To install the reader, follow the instructions below:
1. Connect the reader to the Bus.
2. Install the reader, with the adapter if necessary, on the switch frame available, possibly in a position that leaves it accessible to the
button and to the programming LED located on the side of the reader.
3. Connect the tamper to the input 1 of the reader (yellow wire: interrupt the wire by cutting it and connect the two ends to the tamper).
The TAMPER is the default setting.
4. Connect another optional device to input 2 (green wire: interrupt the wire by cutting it and connect the two ends to the device).
IMPORTANT!
If two readers must be installed near each other in the same box, whether build-in or wall-mounted, leave at
least the space of one switch between them.
For details on conne
ctions (power supplies, inputs, bus, etc. …) see paragraphs
5.11 INSTALLATION OF THE AS500/RPT SUPPLEMENTARY POWER SUPPLY
IMPORTANT!
During installation of the control panel, be very careful to not accidentally damage the board.
5.11.1 Fastening to the wall
Figure 52 - Holes for fastening the AS500/RPT
Position the tamper in position
A
or
S
, according to the type of application desired:
in position
A
, only for protection against opening
in position
S
, for protection against opening and removal, in this case using the expansion screws with for the support of contact.
Connect the tamper connection to the board in both cases.
F
T
Holes for fastening to the wall. Use Ø 6mm plugs depending
on the type of material making up the wall with TCB screw
DIN 7981 3.9 x 32.
D
Holes for fastening 2 optional EP508 expansions
F
Band to fasten power supply cables
T
F
D