171
Wiring for centralising of lighting with relays MTR2000E from Elkron
control panel/expansion
4-wire wiring with pushbutton common line to phase, control panel/expansion with relay
outputs
SD542-9009
D600V
D600V
D600V
C1
A2
C2
B
P
A
1
C1
A2
C2
BP
A1
C1
A
2
C2
BP
A1
N
L
N
L
N
L
R
B
L
R12M
M
V
E
B
R12M
M
V
E
RR
BV
RR
BV
NO
X
-V
1
NO
Y
C
Y
+V
1
C
X
{
CONTROL PANEL SW CONFIGURATION
By
using
the
keypad
or
the
Hi-Connect
programming
software,
configure the output as follows
:
- OUTPUT TYPE = OUTPUT N.L.
- CUSTOMIZE = O. PULSED COMM.
PILOT WIR
E
Co
nt
ro
l P
an
el
/E
xp
an
si
on
Turning On
Turning Off
Manual parallel
centralised controls
(optional)
Turning On
Turning Off
OUTPUT N.L.
O. PULSED COMM.
Pushbutto
n
Pushbutto
n
Pushbutton
Unlimited
number
of modules
V
E
= green wir
e
M
= brown wire
V
= purple wire
B = white wire
R = red wire