E
N
Warning
Procedure
No unit allocated to the room.
allocate actuator
This group has already been allocated.
enter new settings
Display incomplete - control impossible.
calibrate the device
(disconnect the power supply, after reconnecting hold the logo RF Touch,
finish the calibration by touching twice the cross signs that appear in each
corner of the screen)
EPROM memory error!
contact the manufacturer
RTC circuit error!
contact the manufacturer
AT45 circuit error!
contact the manufacturer
Setting of program until midnight and over midnight - at the time of 00:00
there isn´t any action on the actuator.
- setting of time over midnight : set the required "switch ON" time and set
the required "switch OFF" time on 00:00, next day set the switch ON" time
on 00:00 and set the required "switch OFF" time.
- setting of time until midnight: set the required "switch ON" time and set
- setting of time until midnight: set the required "switch ON" time and set
the required "switch OFF" time on 23:59
the required "switch OFF" time on 23:59
Have you lost the password?
please ask the manufacturer for information about further steps
What to do when ...
General Information
With consideration to the transmission of the RF signal ensure that RF components are suitably located in the building where the device is to be installed. The RF Control system must only
be installed in indoor areas. The device has not been designed for outdoor use or use in moist environment, it must not be installed in metal distribution boxes and plastic distribution boxes
with metal doors as this would prevent the transmission of the radio frequency signal. RF Control is not recommended for the control of devices providing for vital life functions or for the
control of risk devices such as pumps, electrical heaters without heat regulators, lifts, pulleys etc. - radio frequency transmission could be hampered with an obstacle, interfered with, the
transmitter battery may become depleted etc. thus disabling the remote control. Not suitable for use in industrial environment.
Do not expose to extreme temperature changes. In case of extreme temperature changes allow approx. 2 hours prior to installation for the RF Touch to adjust to the temperature of the
installation location. This will prevent condensation of moisture in the device and the occurrence of a potential short circuit.
Keep flammable materials away from the device.
The graphic indication of the contact / device status (red/green LED) is only for information and may be influenced by the amount of processed information or the combination of more RF
Touch and RF Pilot control units.
Safety functions in RFSTI-11B and RFSTI-11G actuators: the actuators disconnect the output in case of an accidental communication failure exceeding 25 minutes.
RF Touch Unit Warnings