![ELKHART BRASS Cobra 7250 HD EXM Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/elkhart-brass/cobra-7250-hd-exm/cobra-7250-hd-exm_installation-operating-and-maintenance-instructions_2393094005.webp)
5
SYSTEM COMPONENTS
MONITOR
Monitor – 7250
The
monitor is specially designed to be
compact providing a greatly reduced swing radius. Unique
waterway swivel joints utilize stainless steel thrust rods, and
needle roller thrust bearings, for unprecedented durability in a
range of applications. The
utilizes a cast
vanned waterway to minimize large-scale turbulence. The
monitor can be controlled by hardwired input devices via CAN
bus or by an optional upgraded Radio Frequency (RF) device.
The monitor may be powered with 12 or 24 volts.
Several base options are available for use with the
including a 3” flange, DN80-PN16 flange, 4” flange, 3”
female NPT, and 3” female BSPT. The discharge may be
ordered with either a 3.5” NHT or BSPP thread. The
comes standard with permanent magnet DC gear
motors but may be upgraded with high power, permanent
magnet variable speed DC gear motors. Both motor options
are sealed to NEMA 4 for use in harsh environments.
7250 SD – Standard Duty Motors
7250 HD – Heavy Duty Motors
Caution:
All EXM monitor motors are 12VDC. If using a non-EXM nozzle, another
12VDC nozzle should be used, or nozzle control may not function properly.
NOZZLE
Nozzles –
There is one nozzle rated perfectly for the
.
SM-1500E
The X-Stream series nozzles automatically adjust to
maintain effective stream and maximum reach at
variable flows. These nozzles have been calibrated to
work at lower pressures, from 70 to 75 PSI, to better suit
real world conditions.
SM-1500E;
500 GPM @ 50 PSI - 1500
GPM @ 70 PSI
1893 LPM @ 3.45 BAR – 5678 LPM @ 4.83 BAR
SM-1500E (P/N: 03781801)
Standard 7250 EXM
Monitor (00007205)