The Clear All Function allows the user to remove any Travel Limits, Keep-Out Zones, or Stow
Positions set while in Setup Mode. When the Clear All Function is used, it will remove all of the
previously listed operations. The Clear All Function will not affect calibration points, Motor
Speed, or Preset valve positions.
Put the EXM system into Setup Mode
(reference Part B of the Operating Instructions
section)
Press the OPEN and CLOSE buttons simultaneously
All set Travel Limits, Keep-Out Zones, and Stow Positions will be removed from the system
J. Oscillation
The oscillation function is used to move the monitor back and forth inside a boxed area or
straight horizontal or vertical line specified by the user.
Move the monitor to one corner of the intended boxed area (For a straight horizontal or
vertical line, move monitor to the first line endpoint).
Press the OSCILLATE button
Move the monitor to the opposite corner of the intended boxed area (For a straight
horizontal or vertical line, move monitor to the opposite endpoint of the line.)
Press the OSCILALTE button a second time
The monitor should begin moving up and down, and left and right within the boxed
area. (If setting a horizontal or vertical line, monitor should begin oscillating horizontally
or vertically only.)
If there is no monitor movement for 30 seconds while setting up the oscillation limits, the
monitor will automatically exit oscillate setup
Pressing UP, DOWN, LEFT, RIGHT, or OSCILLATE will stop oscillation of a boxed area
(Pressing LEFT, RIGHT, or OSCILLATE will stop horizontal oscillation while pressing UP,
DOWN, or OSCILLATE will stop vertical oscillation.
o
All other functions can be operated without stopping oscillation.
K. Handheld Controller Sleep / Hibernation Mode
Sleep Mode
–
The Handheld Controller will go into sleep mode after one minute of
inactivity. The blue power LED will blink every three seconds while in sleep mode. Any
button press will wake the unit up.
Hibernation Mode – After 5 minutes of inactivity the handheld will go into hibernate
mode. All LEDs will be off when the handheld is in hibernate mode. The AUX button is
the only button that must be pressed to turn the handheld on at that point.
o
The handheld can be placed in hibernate mode by pressing and holding the AUX
button until the power LED turns off.