background image

Installation Manual (2000000028 Rev B - 12/21) 

Elkay Manufacturing Company

4. Installation Preparation

4.1  Water

CAUTION

Potable Water 

Only

 

 

DO NOT connect this product to a water source that is 

microbiologically unsafe or of unknown quality. Always connect 
the unit to a water main that supplies drinking water only.

Lifting Hazard

 

 

Use two people to move the Countertop unit. The Smartwell 

dispenser weighs 72 lbs. with no water in the chiller. 

Shipping weight of the Smartwell dispenser and accessories 

totals 110 lbs.

NOTICE

DO NOT allow the unit to freeze.

 

1.  Elkay recommends a water pressure of 40 to 105 psi on our cooler 

products. A pressure regulator provided in the install kit reduces the 

pressure to an optimal 50 psi. 

    

NOTICE

Water pressure that does not meet 

the minimum pressure requirement 

of 40 psi can cause damage to the 

internal components. Low pressure may also affect the 

performance of the unit and the taste of the beverage. 

2.  A standard 3/8” diameter inlet water line is recommended (copper or 

FDA-safe plastic).

4.2  Electricity

a.  Access to one standard 120-Volts electric wall receptacle is 

required. The unit must be close enough to socket that the 

supplied power cord reaches without stress or stretching. 

    

NOTICE

DO NOT connect the unit to a 

power strip and DO NOT use an 

extension cord.

b.   A minimum 20 Amp GFCI outlet on a dedicated circuit is 

recommended with a minimum current of 5 amps. Prior to 

installation, ensure that it is possible to disconnect the power 

supply either by removing the plug or by circuit breaker.

    

CAUTION

If the cord or plug 

becomes damaged, 

replace only with a cord 

and plug of the same type. Contact Smartwell Customer Care 

to request a replacement.

4.3  Surroundings

Location Requirements

Install the unit in a clean, dry, well-ventilated room. It is designed to 
function correctly in environments with a temperature between 60°F 
and 80°F.

  

NOTICE

DO NOT place the unit near a 

source of heat.

    

CAUTION

The unit is not intended for 

use by children. Keep the 

areas surrounding the unit 

dry to avoid the risk of injury due to slipping.

1.  The unit requires approx. hole diameter of 3" (7.6 cm) to route the 

tubes to the CO

2

 tank and filter (if installed underneath counter).

 

Note:

   No holes need to be drilled if installing onto the Smartwell 

Cabinet.

 

 

Approx. Hole

Size

Ø 3” (7.6 cm)

24"

4”

36.5"

54.5"

17.6"

1"

19.8"

24"

21.9"

4"

4"

4"

4"

4”

28.5"

4"

4"

Product Dimensions and Minimum Space Requirements

CO

2

 Tank

Countertop Dispenser

Smartwell Cabinet

(Optional)

Note: 20 lb. CO

2

 tank shown for reference. Compatible with smaller tank sizes.

Содержание Smartwell SW1156CS

Страница 1: ...Smartwell Countertop Beverage Dispenser Model SW1156CS Installation Manual Beverage Dispenser WARNING Read the instructions in this manual and retain for future reference ...

Страница 2: ...ter dispenser that gives users the option to create their own custom beverages using a touch screen on the unit or a mobile device for touchless operation Followed carefully these instructions will result in an easy trouble free installation of this Elkay Manufacturing Company Elkay product Any deviations additions or deletions from the described methods without the prior written approval of our S...

Страница 3: ...ormation important to a procedure 2 4 Personal Safety WARNING These warnings indicate a potentially hazardous situation which if not avoided could result in serious injury or death Follow all instructions related to the installation use or maintenance of this product unit Personal Protection Be sure to use all personal protective equipment such as safety glasses sturdy work shoes and cut resistant...

Страница 4: ... supplier including but not limited to Indirect eye contact with CO2 gas may cause mild irritation Direct eye contact with the liquefied gas can freeze the eye causing permanent eye damage or blindness CO2 gas displaces oxygen Make sure there are no CO2 gas leaks in any part of the Smartwell beverage system Direct contact with the liquefied gas can chill or freeze the skin frostbite Tripping Hazar...

Страница 5: ...lied power cord reaches without stress or stretching NOTICE DO NOT connect the unit to a power strip and DO NOT use an extension cord b A minimum 20 Amp GFCI outlet on a dedicated circuit is recommended with a minimum current of 5 amps Prior to installation ensure that it is possible to disconnect the power supply either by removing the plug or by circuit breaker CAUTION If the cord or plug become...

Страница 6: ...ubing 10 feet blue 1000002708 1 2 Coil of insulation for 3 8 water tubing black 101461040560 1 3 Coil of 1 4 O D CO2 tubing white 1000002706 1 4 Quick connect CO2 regulator 1000002468 1 5 Quarter turn water supply shut off valve 1000002470 1 6 Filter 51299C 1 7 Power Cord 1000004819 1 8 Ethernet Cable 15 feet 1000005025 1 9 CO2 Bottle Wall Mounting Bracket 1000005199 1 10 50 psi Water Pressure Reg...

Страница 7: ...regulator to the shut off valve d With 3 8 water tubing connect the other end of the shut off valve to the IN port of the water filter e With 3 8 water tubing connect the OUT port of the water filter to the Dispenser s rear water inlet port f Once all tubing is connected hang the complete filter assembly onto the 2 mounting screws on the Smartwell Cabinet wall 5 Install the CO2 regulator on top of...

Страница 8: ...the unit s main power switch is in the OFF position NOTICE DO NOT plug the unit into a power source at this time The ice bank must be filled with water before the unit is turned ON 2 Use a screwdriver to remove the 2 pan head screws from the panel A of the Countertop unit 3 Slide and remove the panel A from the Countertop unit 4 Use a screwdriver to remove the 4 pan head screws from the panel B of...

Страница 9: ...ly fill the ice bank until the water reaches the maximum fill line on the overflow tube DO NOT over fill the ice bank Note An overflow tube is located behind the Chiller d Once the chiller is filled remove the water line and replace the plug Note A small volume of residual water in the fill line will spill out of the fill port This is completely normal Wipe the residual spilled water with a dry cl...

Страница 10: ...O2 tank to the unit a Install and secure the CO2 tank per the manufacturer s recommendations using the supplied wall bracket if appropriate b Attach the supplied regulator valve onto the CO2 tank c Cut the supplied 1 4 poly tube to the appropriate length d Connect the 1 4 poly tube to the CO2 inlet on the back of the dispenser 5 4 Internet 1 Connect an Ethernet cable from your network into the bac...

Страница 11: ...est connection and check for updates The left hand screen will appear if the unit is not connected to the Internet The right hand screen will appear if the unit is connected to the Internet Press Update to continue Note If there is any issue with connecting after setup then try again to connect the Wi Fi in the Wi Fi screen 4 The unit will search for system updates If there is an update it will be...

Страница 12: ...ughly with warm water and soap to sanitize before touching new pouches Gently lay new flavor and enhancement pouches into slots with the tube side of each pouch coming out towards the front of the unit Note Slot 1 is the furthest to the left 3 Orient each pump and press down firmly onto the pump drive until they have clicked onto the pump drive holder ensuring it is securely fastened 4 Fully inser...

Страница 13: ...nected to the Internet Login and confirm the unit appears in the listing page 11 Once complete place the lid on top and slide back until closed Move the magnetic key into the lock position then remove the key and store in a secure place 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 6 3 Purging the Water Lines 1 Open the water supply valve and purge the trapped air from the water line Note To flu...

Страница 14: ...re reaches 45 psi OPEN 463d 6 4 Set the Water Flow Parameters 1 There are two entries for the flow of water through the dispenser in milliliters per second This number is based on the water pressure at the location of the Smartwell unit Test the water flow and then enter the two numbers into the set up screen The Still Water default is 25 and the Sparkling Water default is 50 a From the Home scree...

Страница 15: ... milliliters in 10 seconds divided by 10 27 Enter 27 into the data field 5 Repeat this process for the Sparkling Water Flow entry The sparkling water will dispense a greater volume in the 10 seconds 6 Press Done once complete 7 Push the back button on the left corner of the set up screen to return to admin screen 6 5 Unit Diagnostics 1 From the Home screen push the Wi Fi signal icon in the upper r...

Страница 16: ... then select Check for Updates Note The Service button will display the system information for this unit Select Check for Updates to manually check for software updates 3 The unit will search for system updates If your system is not up to date the system will begin automatically updating to the latest software If there is no update required press close to exit ELKAY MANUFACTURING COMPANY 1333 BUTT...

Отзывы: