11.3 Various preparatory actions
11.3.1 Remove discharge screw or place in transport position.
Two models of discharge screws exist.
The discharge system in the standard version of the Mega Prof has a 1200 mm screw channel for
a conveying height of 1500 mm.
A discharge system with a 2070 mm screw channel for a conveying height of 2000 mm is also
available as an option. Since the dimensions of the discharge screw are different here, a different
securing system and an alternative method for placing the machine in the transport position are
provided.
Caution:
When removing the discharge channel or placing it in the transport position, you
must always use the special cover plate supplied to seal off the discharge open-
ing of the collector that becomes visible.
11.3.1.1 Standard discharge screw
Placing the discharge screw in the transport position:
• To reduce the length of the machine during transportation, you can move the discharge chan-
nel upwards and lock it in this position. But fi rst allow the collector chamber and the screw to
continue to rotate until all chippings have disappeared.
• Always make sure that the machine is completely switched OFF before releasing the discharge
channel. Release the clamp that secures the discharge channel to be collector.
• Remove the clamp from the collector.
• Then turn the discharge screw to the right.
• Opening can be more diffi cult than expected : The conical clamp connection between the two
halves of the screw can be tight. Pull or turn the transport screw alongside the discharge fl ap at
the top of the discharge channel. This will make it easier to separate the two halves of the screw.
• Lock the screw with the special pin provided for this purpose.