8.1.
Wiring Diagram (S05-S60)
Figure 23: Wiring diagram for S05-S60.
CAUTION
In case of fuse line protection, always install the fuse failure detection device,
which must disable the inverter to avoid single-phase operation of the equipment.
NOTE
Please refer to the OPTIONAL INPUT-OUTPUT REACTORS section for the
applicable input and output reactors. When ordering Sinus K drives ranging from
S20 to S60, please state if reactors are to be installed on the equipment..
NOTE
The wiring diagram relates to factory-setting. Please refer to the Power Terminal
Lay-out section for the ID numbers of the wiring terminals.
NOTE
When no DC reactor is used, terminals 47D and 47+ must be short-circuited
(factory setting).
CAUTION
For S60 inverters only: if the supply voltage is not 400Vac rated, the connections
of the internal auxiliary transformer must be changed accordingly. (See Figure 38)