INSTALLATION
SINUS K
INSTRUCTIONS
162/
191
13.6.3.
I
NSTALLING THE
E
NCODER
B
OARD ON THE
I
NVERTER
1) Remove voltage from the inverter and wait at least 5 minutes.
2) Remove the cover allowing to gain access to the inverter control terminals. The fixing spacers and the signal
connector are located on the left.
Figure 78: Position of the slot for the installation of the encoder board.
3) Fit the encoder board and make sure that all contacts enter the relevant housing in the signal connector.
Fasten the encoder board to the metal columns using the screws supplied.
4) Configure the dip-switch and the jumper located on the encoder board based on the type of encoder being
used. Check that supply voltage in terminal board output is correct.
5) Turn on the inverter and set the parameters relating to the encoder feedback (see Sinus K’s Programming
Instructions Manual).
Figure 79: Encoder board fastened to its slot.
Содержание SINUS K
Страница 49: ...SINUS K INSTALLATION INSTRUCTIONS 49 191 S65 T S R U V W S64 Figure 8 Installation Example of a SINUS K S64 S65...
Страница 157: ...SINUS K INSTALLATION INSTRUCTIONS 157 191 Figure 75 Mechanical features of an AC 3 phase inductance...
Страница 186: ...INSTALLATION SINUS K INSTRUCTIONS 186 191 15 DECLARATIONS OF CONFORMITY...
Страница 187: ...SINUS K INSTALLATION INSTRUCTIONS 187 191...
Страница 188: ...INSTALLATION SINUS K INSTRUCTIONS 188 191...
Страница 189: ...SINUS K INSTALLATION INSTRUCTIONS 189 191...
Страница 190: ...INSTALLATION SINUS K INSTRUCTIONS 190 191...
Страница 191: ...SINUS K INSTALLATION INSTRUCTIONS 191 191...