background image

29

INSTALLER INFORMATION

Commissioning the appliance

A soundness test MUST be made before the in-
stalled stove is left with the customer.

Ensure that the fire is burning at full rate for a 
minimum of 5 minutes to warm the flue.

If there are problems, the flue may require 
attention.

The stove will produce an odour and/or smoke 
for the first few hours of use. Please ventilate the 
room. Also please note that during this initial burn-
ing period, a grey dust deposit will be formed on 
the inside of the window, please clean this before 
leaving the appliance with the customer.

Gravel Arrangements / Blackstones / 

Brilliants 

Ensure that the Grate , is sitting firmly in the base 
of the fire box, with the long slot in the centre of the 
Grate aligning with the centre slots on the Burner 
Tube. The Pilot flame must be visible through the 
grate and the cut-out in the Pilot Shield.

Scatter evenly the Gravel over the top of the Grate 
and Burner. Make sure that some holes of grate 
are still visible. Ensure that none of the gravel 
enters the pilot enclosure.

The Gravel arrangement is now complete, 

How-

ever, it is important to check that  no stones 
have entered the pilot area and the cross 
lighting is good before the glass is replaced.

Gravel Arrangement

12

INSTALLATION/FERNBEDIENUNG

Einlegen von Kiesel Vesuvius 100 & 

Vesuvius 140

Sollten Sie sich für die Kiesel entschieden 

haben, können diese jetzt wie auf den 

Abbildungen hier unten eingelegt werden.

-  Legen Sie nie mehr als eine Schicht 

Kiesel auf den Boden und achten sie 

darauf, dass die Zündflamme immer gut 

sichtbar ist.

-  

!!Achten Sie darauf, dass der 

Zündbrenner sowie auch der Platz 

darum her frei bleiben!!

-  

Wenn die Steine nicht gut eingelegt 

werden-beispielsweise wenn sie 

aufeinander gestapelt werden- kann 

das als Konsequenz haben das der 

Hauptbrenner nicht ordentlich zündet. 

Das kann sehr gefährlich sein.

4) 

Die Drahtlose Fernbedienung

Das Gerät wird mit einer drahtlosen 

Fernbedienung geliefert. Die Zündung, 

das Einregeln der Flammenhöhe sowie 

das Ausschalten werden über die 

Fernbedienung gelenkt, die wiederum 

einen Empfänger im Schaltkasten 

ansteuert.

In der Bedienungsanleitung, Kapitel 

„Drahtlose Fernbedienung“ wird die 

Bedienung des Geräts einschließlich der 

Funktion der Fernbedienung beschrieben.

Kiesel, nur eine schicht

Содержание vesuvius 100

Страница 1: ...h the customer for future reference User and installation manual Vesuvius 100 Vesuvius 140 WARNING THE COMBUSTION CHAMBER OF THIS STOVE SHOULD ONLY BE OPENED AND SERVICED BY A REGISTERED GAS INSTALLER...

Страница 2: ...ination 13 Concentric Flue Parts Identification 14 Rigid Balanced Flue Connection Possibilities 21 Vertical Roof Terminations 22 Installing Remote Control Electronic Ignition System GV60 25 Arranging...

Страница 3: ...lidation Regulations issued by GENERAL INFORMATION Important Safety Notice This appliance has a ceramic Fire bed arrange ment this contains Refractory Ceramic Fibres which are man made vitreous silica...

Страница 4: ...herefore it is of importance that you do not use the appliance shortly after a renovation of the home Because of the natural circulation of air moist and volatile components from paint building materi...

Страница 5: ...ma tion of a correct communication Caution When installing a new remote control or receiver you must set a new communica tion code 2 5 INFORMATIE VOOR DE GEBRUIKER 1 2 3 1 2 Afstandsbediening met voll...

Страница 6: ...ite the appliance I g n i t e t h e a p p l i a n c e a s f o l l o w s Simultaneously press the buttons and on the remote control Let go of the buttons when a short sound signal indicates that the ig...

Страница 7: ...OFF and small flame until the correct display appears Time The display can indicate time After placing the battery or simultaneously press ing large flame and small flame the time indication will fla...

Страница 8: ...rs the temperature returns to 15 C at 10 pm Example By using the Y TEMP function you can keep the day temperature at 20 C while you use the 4 TEMP function at night to maintain a temperature of 15 C S...

Страница 9: ...tion Follow the steps below for activating the timer control Place the appliance in the standby pilot burner position using button small flame Set the day night temperature if you have not yet done so...

Страница 10: ...it must be professionally cleaned and certified as being sound and fit for use The European CE approval on this appliance is restricted to the Flue systems as specified by the supplier thus the appli...

Страница 11: ...rame Buildings from the CORGI installer series in the UK Carport or Building Extension Where a flue terminal is sited within a carport or building extension it should have at least two completely open...

Страница 12: ...il pipe 300 H From an internal or external corner 600 I Above ground roof or balcony level 300 J From a surface facing the terminal 600 K From a terminal facing the terminal 600 L From an opening in t...

Страница 13: ...1 m higher than the intake supply opening or a window that can be opened If the required distance cannot be achieved the position of the outlet must be at least 1 m above the highest facade roof Impor...

Страница 14: ...centric Flue Pipe 1m Length US 100 100 US 100 130 4 Locking Band USKB 100 USKB 130 5 Protection Band USAB 100 USAB 130 6 Concentric Flue Pipe Adjustable Length 50 300mm USPP 100 USPP 130 7 Vertical Te...

Страница 15: ...15 INSTALLER INFORMATION...

Страница 16: ...16 INSTALLER INFORMATION...

Страница 17: ...17 INSTALLER INFORMATION...

Страница 18: ...18 INSTALLER INFORMATION...

Страница 19: ...19 INSTALLER INFORMATION 22 USVK 100 130 REDUCER 130 100 23 USDHC 130 HORIZONTAL TERMINAL 130...

Страница 20: ...20 INSTALLER INFORMATION 24 USBI 100 130 Elbow 90 with inspection cover 25 USI 100 130 Inspection Element...

Страница 21: ...ter vertical gives maximum horizontal 1 5 meter 2 0 meter vertical gives maximum horizontal 2 0 meter 3 0 meter vertical gives maximum horizontal 3 0 meter 21 INFORMATIE VOOR DE INSTALLATEUR Aansluitm...

Страница 22: ...on classification 31 it is important to fit a flue restric tor across the flue outlet inside the fire Roof terminations will need the 60 mm flue restrictors fitting This is delivered with the fire Dis...

Страница 23: ...USVK naar afvoermateriaal 150 100 te gebruiken INSTALLER INFORMATION Vertical Roof Mounted Termination with Elbow for Rigid Concentric Flue For Vesuvius 140 we recommend using flue reducer USVK to fl...

Страница 24: ...mate riaal 150 100 te gebruiken INSTALLER INFORMATION Vertical Roof Mounted Termination with Angled Elbow for Rigid Concentric Flue For Vesuvius 140 we recommend using flue reducer USVK to flue dimens...

Страница 25: ...respectively Setting the electronics code The receiver has to select the code of the handset please follow the procedure 1 Power up handset 2 Power up receiver LED flashes 3 Push reset button on rece...

Страница 26: ...slot in the centre of the Grate aligning with the centre slots on the Burner Tube The Pilot flame must be visible through the grate and the cut out in the Pilot Shield Make sure there is a 1 cm gap b...

Страница 27: ...nd the cut out in the Pilot Shield Scatter the Embers over the grate and the chippings over the burner top Ensure no embers or chips enter the Pilot Area keeping the gap between the up fold on the gra...

Страница 28: ...Finally check the pilot is clear no embers have entered the Pilot area and the cross lighting is good before the glass is replaced The Vesuvius 140 does have a second thermo element Also this area sho...

Страница 29: ...enclosure The Gravel arrangement is now complete How ever it is important to check that no stones have entered the pilot area and the cross lighting is good before the glass is replaced Gravel Arrang...

Страница 30: ...ouwtips Lees eerst de algemene informatie over gesloten haarden welke u voor in deze gebruiksaanwijzing kunt vinden Zorg ervoor dat het gasregelblok en de gasaansluiting na installatie te allen tijde...

Страница 31: ...APPEN 1 t m 4 IN INSTALLER INFORMATION INSTALLATION OF THE GLASS WINDOW 1 See figure 1 Before placing the glass check the glass sealing rope is in good condition and makes an effective seal Be sure th...

Страница 32: ...e frame by them The bolds make sure that the glass doesn t break when the fire heats up 33 INFORMATIE VOOR DE INSTALLATEUR Schema 2 Let op De glasplaat van de Vesuvius haard heeft aan de bovenzijde ee...

Страница 33: ...e gebroken of beschadigde onderdelen zie eerder in deze handleiding Controleer het keramische koord op de glasplaat en plaats de glasplaat terug Controleer de installatie op gaslekken Controleer de af...

Страница 34: ...re mote control within 20 sec until you hear an extra long sound signal confirming that the new code has been set 2 Replace batteries Caution Avoid short circuit between the batteries and metal parts...

Страница 35: ...de directly next to the magnet nut at the rear of the gas control The voltage should be at least 5mV within 20 seconds It may not be lower when the appliance is warm If the voltage is too low the ther...

Страница 36: ...ON Vesuvius 100 Vesuvius 140 117 5 1010 178 1206 554 970 150 358 1014 358 178 621 362 115 MIN 35 48 180 912 105 1014 282 250 297 117 5 297 282 1354 250 1252 105 280 358 165 3 608 362 102 MIN 40 48 167...

Страница 37: ...37 NOTES...

Страница 38: ...20 20mbar EE Estonia I2H G20 20mbar ES Spain I2H G20 20mbar FI Finland I2H G20 20mbar FR France I2E G20 G25 20 25mbar GB United Kingdom I2H G20 20mbar GR Greece I2H G20 20mbar HR Croatia I2H G20 20mba...

Страница 39: ...Kingdom I3B P G30 G31 30mbar I3 G30 G31 28 30 37mbar GR Greece I3B P G30 G31 30mbar I3 G30 G31 28 30 37mbar HR Croatia I3B P G30 G31 30mbar HU Hungary I3B P G30 G31 30mbar IE Ireland I3 G30 G31 28 30...

Страница 40: ...ual We hereby declare that the design and construction of Element4 s atmospheric gas heating appliance comply with the essential requirements of the Gas Appliance Directive Product atmospheric gas hea...

Страница 41: ...y The factory warranty is valid for 12 months after date of purchase Vesuvius 140 PIN 0359CN1268 Natural Gas LPG Gas Category I2H I3B P I3 Supply Pressure mbar 20 30 28 30 37 Nominal Input 14 0 7 9 7...

Страница 42: ...42 NOTES...

Страница 43: ...43 NOTES...

Страница 44: ...Element4 B V Paxtonstraat 23 8013 RP Zwolle The Netherlands September 2014...

Отзывы: