background image

14

Concentric Flue Parts Identification

The following pages identify the parts that may be used in the Balanced Flue installation of this appliance.

The Item number in the table refers to the item number of the part in the Identification pages, this Item 

number is also the number that will be used to identify parts in the Installation suggestion diagrams.

INSTALLER INFORMATION

Item Description

Part No.

 

 

Ø100

Ø130

A

Appliance

 

 

B

Appliance Connector

 

 

C

Flue Adaptor

 

 

D

Chimney or Flue, Fully Gas Tight Ø150 minimum

 

 

E

Chimney or Flue, Fully Gas Tight Ø160 minimum

 

 

F

Stainless Steel Flexible Chimney Liner Ø100, AISI 316Ti  

 

G

Stainless Steel Flexible Chimney Liner Ø150, AISI 316Ti  

 

1

Concentric Flue Pipe 250mm Length

US 25 100

US 25 130

2

Concentric Flue Pipe 500mm Length

US 50 100

US 50 130

3

Concentric Flue Pipe 1m Length

US 100 100

US 100 130

4

Locking Band

USKB 100

USKB 130

5

Protection Band

USAB 100

USAB 130

6

Concentric Flue Pipe Adjustable Length 50 - 300mm USPP 100

USPP 130

7

Vertical Terminal

USDVC2 100  

8

Horizontal Terminal (Excentric Exit) Ø100

USDHCE 100  

9

Mounting Band

USEB 100

USEB 130

10

Wall Band Adjustable

USMB 100

USMB 130

11

Concentric Flue 90°

USB 90 100

USB 90 130

12

Concentric Flue 45°

USB 45 100

USB 45 130

13

Concentric Flue 15°

USB 15 100

USB 15 130

14

Storm Collar

USSR 100

USSR 130

15

Flat Roof Flashing (Aluminium)

USDPAL 100 USDPAL 130

16

Flat Roof Flashing

USDP 100

USDP 130

 

 

 

 

18

Slope Roof Flashing 5° - 30°

USDH 100

USDH 130

19

Slope Roof Flashing 20° - 45°

USLS 100

USLS 130

20

Adjustable Roof Plate (Supplied as pair)

USCP 100

USCP 130

21

Wall Cover

USMPG 100 USMPG 130

22

Flue reducer Ø130 - Ø100

 

USVK 10 130

23

Horizontal Terminal (Excentric Exit) Ø130

 

USDHC 130

24

Concentric Flue 90° with Inspection Cover

USBI 100

USBI 130

25

Inspection Element

USI 100

USI 130

Содержание vesuvius 100

Страница 1: ...h the customer for future reference User and installation manual Vesuvius 100 Vesuvius 140 WARNING THE COMBUSTION CHAMBER OF THIS STOVE SHOULD ONLY BE OPENED AND SERVICED BY A REGISTERED GAS INSTALLER...

Страница 2: ...ination 13 Concentric Flue Parts Identification 14 Rigid Balanced Flue Connection Possibilities 21 Vertical Roof Terminations 22 Installing Remote Control Electronic Ignition System GV60 25 Arranging...

Страница 3: ...lidation Regulations issued by GENERAL INFORMATION Important Safety Notice This appliance has a ceramic Fire bed arrange ment this contains Refractory Ceramic Fibres which are man made vitreous silica...

Страница 4: ...herefore it is of importance that you do not use the appliance shortly after a renovation of the home Because of the natural circulation of air moist and volatile components from paint building materi...

Страница 5: ...ma tion of a correct communication Caution When installing a new remote control or receiver you must set a new communica tion code 2 5 INFORMATIE VOOR DE GEBRUIKER 1 2 3 1 2 Afstandsbediening met voll...

Страница 6: ...ite the appliance I g n i t e t h e a p p l i a n c e a s f o l l o w s Simultaneously press the buttons and on the remote control Let go of the buttons when a short sound signal indicates that the ig...

Страница 7: ...OFF and small flame until the correct display appears Time The display can indicate time After placing the battery or simultaneously press ing large flame and small flame the time indication will fla...

Страница 8: ...rs the temperature returns to 15 C at 10 pm Example By using the Y TEMP function you can keep the day temperature at 20 C while you use the 4 TEMP function at night to maintain a temperature of 15 C S...

Страница 9: ...tion Follow the steps below for activating the timer control Place the appliance in the standby pilot burner position using button small flame Set the day night temperature if you have not yet done so...

Страница 10: ...it must be professionally cleaned and certified as being sound and fit for use The European CE approval on this appliance is restricted to the Flue systems as specified by the supplier thus the appli...

Страница 11: ...rame Buildings from the CORGI installer series in the UK Carport or Building Extension Where a flue terminal is sited within a carport or building extension it should have at least two completely open...

Страница 12: ...il pipe 300 H From an internal or external corner 600 I Above ground roof or balcony level 300 J From a surface facing the terminal 600 K From a terminal facing the terminal 600 L From an opening in t...

Страница 13: ...1 m higher than the intake supply opening or a window that can be opened If the required distance cannot be achieved the position of the outlet must be at least 1 m above the highest facade roof Impor...

Страница 14: ...centric Flue Pipe 1m Length US 100 100 US 100 130 4 Locking Band USKB 100 USKB 130 5 Protection Band USAB 100 USAB 130 6 Concentric Flue Pipe Adjustable Length 50 300mm USPP 100 USPP 130 7 Vertical Te...

Страница 15: ...15 INSTALLER INFORMATION...

Страница 16: ...16 INSTALLER INFORMATION...

Страница 17: ...17 INSTALLER INFORMATION...

Страница 18: ...18 INSTALLER INFORMATION...

Страница 19: ...19 INSTALLER INFORMATION 22 USVK 100 130 REDUCER 130 100 23 USDHC 130 HORIZONTAL TERMINAL 130...

Страница 20: ...20 INSTALLER INFORMATION 24 USBI 100 130 Elbow 90 with inspection cover 25 USI 100 130 Inspection Element...

Страница 21: ...ter vertical gives maximum horizontal 1 5 meter 2 0 meter vertical gives maximum horizontal 2 0 meter 3 0 meter vertical gives maximum horizontal 3 0 meter 21 INFORMATIE VOOR DE INSTALLATEUR Aansluitm...

Страница 22: ...on classification 31 it is important to fit a flue restric tor across the flue outlet inside the fire Roof terminations will need the 60 mm flue restrictors fitting This is delivered with the fire Dis...

Страница 23: ...USVK naar afvoermateriaal 150 100 te gebruiken INSTALLER INFORMATION Vertical Roof Mounted Termination with Elbow for Rigid Concentric Flue For Vesuvius 140 we recommend using flue reducer USVK to fl...

Страница 24: ...mate riaal 150 100 te gebruiken INSTALLER INFORMATION Vertical Roof Mounted Termination with Angled Elbow for Rigid Concentric Flue For Vesuvius 140 we recommend using flue reducer USVK to flue dimens...

Страница 25: ...respectively Setting the electronics code The receiver has to select the code of the handset please follow the procedure 1 Power up handset 2 Power up receiver LED flashes 3 Push reset button on rece...

Страница 26: ...slot in the centre of the Grate aligning with the centre slots on the Burner Tube The Pilot flame must be visible through the grate and the cut out in the Pilot Shield Make sure there is a 1 cm gap b...

Страница 27: ...nd the cut out in the Pilot Shield Scatter the Embers over the grate and the chippings over the burner top Ensure no embers or chips enter the Pilot Area keeping the gap between the up fold on the gra...

Страница 28: ...Finally check the pilot is clear no embers have entered the Pilot area and the cross lighting is good before the glass is replaced The Vesuvius 140 does have a second thermo element Also this area sho...

Страница 29: ...enclosure The Gravel arrangement is now complete How ever it is important to check that no stones have entered the pilot area and the cross lighting is good before the glass is replaced Gravel Arrang...

Страница 30: ...ouwtips Lees eerst de algemene informatie over gesloten haarden welke u voor in deze gebruiksaanwijzing kunt vinden Zorg ervoor dat het gasregelblok en de gasaansluiting na installatie te allen tijde...

Страница 31: ...APPEN 1 t m 4 IN INSTALLER INFORMATION INSTALLATION OF THE GLASS WINDOW 1 See figure 1 Before placing the glass check the glass sealing rope is in good condition and makes an effective seal Be sure th...

Страница 32: ...e frame by them The bolds make sure that the glass doesn t break when the fire heats up 33 INFORMATIE VOOR DE INSTALLATEUR Schema 2 Let op De glasplaat van de Vesuvius haard heeft aan de bovenzijde ee...

Страница 33: ...e gebroken of beschadigde onderdelen zie eerder in deze handleiding Controleer het keramische koord op de glasplaat en plaats de glasplaat terug Controleer de installatie op gaslekken Controleer de af...

Страница 34: ...re mote control within 20 sec until you hear an extra long sound signal confirming that the new code has been set 2 Replace batteries Caution Avoid short circuit between the batteries and metal parts...

Страница 35: ...de directly next to the magnet nut at the rear of the gas control The voltage should be at least 5mV within 20 seconds It may not be lower when the appliance is warm If the voltage is too low the ther...

Страница 36: ...ON Vesuvius 100 Vesuvius 140 117 5 1010 178 1206 554 970 150 358 1014 358 178 621 362 115 MIN 35 48 180 912 105 1014 282 250 297 117 5 297 282 1354 250 1252 105 280 358 165 3 608 362 102 MIN 40 48 167...

Страница 37: ...37 NOTES...

Страница 38: ...20 20mbar EE Estonia I2H G20 20mbar ES Spain I2H G20 20mbar FI Finland I2H G20 20mbar FR France I2E G20 G25 20 25mbar GB United Kingdom I2H G20 20mbar GR Greece I2H G20 20mbar HR Croatia I2H G20 20mba...

Страница 39: ...Kingdom I3B P G30 G31 30mbar I3 G30 G31 28 30 37mbar GR Greece I3B P G30 G31 30mbar I3 G30 G31 28 30 37mbar HR Croatia I3B P G30 G31 30mbar HU Hungary I3B P G30 G31 30mbar IE Ireland I3 G30 G31 28 30...

Страница 40: ...ual We hereby declare that the design and construction of Element4 s atmospheric gas heating appliance comply with the essential requirements of the Gas Appliance Directive Product atmospheric gas hea...

Страница 41: ...y The factory warranty is valid for 12 months after date of purchase Vesuvius 140 PIN 0359CN1268 Natural Gas LPG Gas Category I2H I3B P I3 Supply Pressure mbar 20 30 28 30 37 Nominal Input 14 0 7 9 7...

Страница 42: ...42 NOTES...

Страница 43: ...43 NOTES...

Страница 44: ...Element4 B V Paxtonstraat 23 8013 RP Zwolle The Netherlands September 2014...