7
USER INFORMATION
Flame height / standby
The flame height can be adjusted continuously by
using the buttons
and
By continuing to lower the flame height, the ap-
pliance can be set to the standby position; this
means that only the pilot burner will still be burn-
ing.
Press button
(small flame) to lower the
flame height and/or to set the appliance in the
standby position.
Press the button
(large flame) to raise the
flame height and/or to switch on the main burner
from the standby (pilot burner) position.
Caution - If you continue to press down button
(large flame) on the remote control,
the main burner should be largely ignited
within about 10 seconds. If this is not the
case, you must close the gas tap and warn
your installer;
- If the appliance ignites with a pop sound,
you must close the gas tap and contact your
installer
.
Switching off
Switch the appliance off by pressing the OFF
button.
The pilot burner will also go out.
Temperature display
The room temperature can be indicated on the
display in degrees Celsius (°C) using a 24 hour
clock or degrees Fahrenheit (°F) using a 12 hour
clock.
Simultaneously press OFF
and (small
flame)
, until the correct display appears.
Time
The display can indicate time.
After placing the battery or simultaneously press-
ing
(large flame) and
(small flame), the time indication will flash on the
display and you will be able
to adjust the time.
Simultaneously press and until the time indication
flashes on the display.
Press the button
(large flame)
to set the hours.
Press the button
(small flame) to set the
minutes.
Press OFF
to return to the MAN position,
or wait for the system to automatically return to
the MAN position.
Thermostat function
Using the thermostat function you can set
two temperatures, which can be controlled
thermostatically. These temperatures are referred
to as day temperature and night temperature.
The
✹
TEMP and TEMP symbols on
the display refer to day and night temperature
respectively.
The room temperature is compared to the set
day/night temperature and then the flame height
is automatically controlled in order to reach the
set temperature.To be able to use the day/night
temperature function, the appliance must be
in the standby position.
!Caution - Always leave the remote control at
the same place, so that the thermostat is
able to ‘feel’ the room temperature;
- Make sure this place is free from influences
such as draught, heat from radiators
and direct sunlight.
Содержание vesuvius 100
Страница 15: ...15 INSTALLER INFORMATION...
Страница 16: ...16 INSTALLER INFORMATION...
Страница 17: ...17 INSTALLER INFORMATION...
Страница 18: ...18 INSTALLER INFORMATION...
Страница 19: ...19 INSTALLER INFORMATION 22 USVK 100 130 REDUCER 130 100 23 USDHC 130 HORIZONTAL TERMINAL 130...
Страница 20: ...20 INSTALLER INFORMATION 24 USBI 100 130 Elbow 90 with inspection cover 25 USI 100 130 Inspection Element...
Страница 37: ...37 NOTES...
Страница 42: ...42 NOTES...
Страница 43: ...43 NOTES...
Страница 44: ...Element4 B V Paxtonstraat 23 8013 RP Zwolle The Netherlands September 2014...