
13
Service
The pump is maintenance free. Defects must
only be repaired by an authorised service
station.
Cleaning
When the pump is often transported in the course
of operation, it should be cleaned out with clear
water after every use.
In case of stationary installation, the function of
the bating switch should be checked every 3
months.
All fibrous particles which may have built-up
inside the pump housing should be removed with a
water jet.
Every 3 months the shaft ground and as should
be cleaned from mud.
Remove deposits on the floater with clear water.
The pump must not be
opened by the user.
TECHNICAL DATA
PVG100
Type
laden water
Mains voltage
220~240 V
Mains frequency
50 Hz
length of the electrical cable
6m
Power input
0.75kW
No load speed
2850 min
-1
Max. pump capacity
367l/min
Max. lift
11m
Max. submerging depth m
5m
Max. grain size
38mm
Max. water temperature
35°C
Type of protection / Insulation class
IP68
Gewicht kg
17.5
PVG150
Type
laden water
Mains voltage
220~240 V
Mains frequency
50 Hz
length of the electrical cable
6m
Power input
1.1kW
No load speed
2850 min
-1
Max. pump capacity
450l/min
Max. lift
13.5m
Max. submerging depth m
5m
Max. grain size
38mm
Max. water temperature
35°C
Type of protection / Insulation class
IP68
Gewicht kg
19.5
PVG200
Type
laden water
Mains voltage
220~240 V
Mains frequency
50 Hz
length of the electrical cable
6m
Power input
1.5kW
No load speed
2850 min
-1
Max. pump capacity
517l/min
Max. lift
15m
Max. submerging depth m
5m
Max. grain size
38mm
Max. water temperature
35°C
Type of protection / Insulation class
IP68
Gewicht kg
21.5
ATTENTION !
The sound power pressure may
exceed 85 dB(A), in this case
individual hearing protection
must be worn.
Weighted root mean square acceleration according
to relevant standard. :
< 2.5 m/s²
The declared vibration total value has
been measured in accordance with a standard
test method and may be used for comparing one
tool with another that the declared vibration total
value may also be used in a preliminary
assessment of exposure.
A warning that the vibration emission
during actual use of the power tool can differ
from the declared total value depending on the
ways in which the tool is used and of the need to
identify safety measures to protect the operator
that are based on an estimation of exposure in
the actual conditions of use (taking account of
all parts of the operating cycle such as the times
when the tool is switched off and when it is
running idle in addition to the trigger time).
SERVICE DEPARTMENT
_ Damaged switches must be replaced by our after-
sales service department.
_ If replacing the power cord is necessary, it
should be done by the manufacturer or his agent
to avoid a hazard.
Содержание 5411074170189
Страница 2: ...2 4 1 3 5 2 6...
Страница 23: ...23 PVG100 PGV150 PGV200...