Symbols : 
 

 

Denotes risk of personal 

injury or damage to the tool. 

 

Read manual before use. 

 

Delivery height max 

 

Size : Foreign bodies 

 

Delivery rate max.. 

 

Immersion depth max. 

 

In accordance with essential 

applicable safety standards 

of European directives 

IPX* 

Degree of protection IP 

 

ELECTRICAL SAFETY

 

 

Always check that the power 

supply corresponds to the 

voltage on the rating plate. 

 

DESCRIPTION 

1. motor housing  
2. water inlet  
3. water outlet  
4. cable & plug  
5. floating switch  
6. carrying handle  
 
 

INSTALLATION  
  

Connecting the outlet pipe 

 

Connect the outlet pipe to the outlet 

opening. 
 
Please note!  
You should never install the pump by suspending it 
unsupported from its delivery pipe or power cable. 
The submersible motor pump must be suspended 
from the specially provided handle or be placed on 
the bottom of the shaft. To guarantee that the pump 
works properly, the bottom of the shaft must be kept 
free of sludge and dirt of all kinds.  
If the level of water sinks too far, any sludge in the 
shaft will dry out quickly and stop the pump from 

starting up. ,Therefore it is necessary to check the 
submersible motor pump regularly (by carrying out 
start-up tests). The floater is adjusted in a way that 
the pump can immediately be started  
 
Note!  
The pump shaft should have minimum dimensions 
of 40 x 40 x 50 cm, so that the floating switch can 
move freely.

  

 
Mains supply  
Your new submersible pump is equipped with a 
shock-proof plug according to regulations. The 
pump is designed to be connected to a 220/240V - 
50 Hz earthed socket.  
 
Important Note!  
If the mains cable or plug suffers any damage from 
external action, repairs to the cable are prohibited.  
 

SETTING TO WORK  

After having read these instructions carefully, you 
can set your pump to work, reconsidering the 
following:  
 

 Check if the pump rests on the ground of the 

shaft.  

 Check of pressure cord has been attached 

properly.  

 Check if electrical connection is 220/240V - 50 

Hz.  

 Check if socket is in good condition.  

 Make sure that water and humidity can never 

come to the mains supply.  

 Avoid pump running dry.  

 

 

Before installing or moving 

the pump always remove the 

mains plug from the wall 

socket. 

 
Switching on and off 

 

To switch on the pump, insert the mains 

plug in the wall socket. 

 

To switch off the pump, remove the mains 

plug from the wall socket. 
The pump only operates when the float 
switch floats. This prevents the pump 
from running dry during operation. 
 
  

CLEANING AND MAINTENANCE  

 

 

Attention ! 

Before performing any work 

on the equipment, pull the 

power plug. 

 

 

Never use solvents such as 

petrol, alcohol, ammonia 

water, etc. These solvents 

may damage the plastic 

parts. 

 
 
 
 

Содержание 5411074170189

Страница 1: ...B SUBMERGIBLE PUMP ORIGINAL INSTRUCTIONS DE TAUCHPUMPE BERSETZUNG DER ORIGINALANLEITUNG IT POMPA SOMMERGIBILE TRADUZIONE DELLE ISTRUZIONI ORIGINALI S52 M12 Y2015 Sous r serve de modifications Technisc...

Страница 2: ...2 4 1 3 5 2 6...

Страница 3: ...ectricien agr Toutes les connexions enfich es lectriques doivent tre effectu es dans une zone prot g e contre les inondations Des rallonges non adapt es peuvent pr senter des risques N utiliser en ple...

Страница 4: ...la sur le fond du puits Afin d assurer le bon fonctionnement de la pompe il faut que le fond du puits soit toujours exempt de boue ou d autres impuret s Dans le cas d un niveau d eau trop bas la boue...

Страница 5: ...ns le bo tier de la pompe Tous les trois mois enlever la boue du fond du puits et nettoyer les parois du puits Enlever les d p ts sur l interrupteur flotteur avec de l eau claire La pompe ne doit pas...

Страница 6: ...ce Apr s Vente r pond vos questions concernant la r paration et l entretien de votre produit et les pi ces de rechange Vous trouverez des vues clat es ainsi que des informations concernant les pi ces...

Страница 7: ...en in een overstromingsveilige sector aangebracht worden Ongeschikte verlengingskabels kunnen gevaarlijk zijn Gebruik in de open lucht alleen daarvoor goedgekeurde en dienovereenkomstig gemerkte verle...

Страница 8: ...itdrogen en de pomp verhinderen aan te slaan Daarom is het noodzakelijk om de dompelmotorpomp regelmatig te controleren aanlooptest uitvoeren De vlotterschakelaar is dusdanig ingesteld dat een onmidde...

Страница 9: ...ijk bevrijden en ook de schachtwanden reinigen Afzetting op de vlotterschakelaar met zuiver water schoonmaken De pomp mag niet door de gebruiker worden geopend TECHNISCHE GEGEVENS PVG100 Type Water Vu...

Страница 10: ...NSERVICE EN GEBRUIKSADVIEZEN Onze klantenservice beantwoordt uw vragen over reparatie en onderhoud van uw product en over vervangingsonderdelen Explosietekeningen en informatie over vervangingsonderde...

Страница 11: ...utdoors which have been approved for this purpose and labelled with a sufficient cable cross section The plug and coupling of the extension cable used must be spray watertight Do not use the mains cab...

Страница 12: ...can immediately be started Note The pump shaft should have minimum dimensions of 40 x 40 x 50 cm so that the floating switch can move freely Mains supply Your new submersible pump is equipped with a...

Страница 13: ...icht kg 19 5 PVG200 Type laden water Mains voltage 220 240 V Mains frequency 50 Hz length of the electrical cable 6m Power input 1 5kW No load speed 2850 min 1 Max pump capacity 517l min Max lift 15m...

Страница 14: ...caabano it Head office SOGGIA s a s di Soggia Gabriele e C via Busonera 24 35031 Abano Terme PD Italy Tel 39 049 8591796 Fax 39 049 2131357 Web address www elettromeccanicaabano it P IVA IT04520600281...

Страница 15: ...austauschen lassen Alle elektrischen Steckerverbindungen sind im berflutungssicheren Bereich anzubringen Ungeeignete Verl ngerungsleitungen k nnen gef hrlich sein Verwenden Sie im Freien nur daf r zu...

Страница 16: ...aufliegen Um eine einwandfreie Funktion der Pumpe zu gew hrleisten muss der Schachtboden immer frei von Schlamm oder sonstigen Verunreinigungen sein Bei zu geringem Wasserstand kann der im Schacht be...

Страница 17: ...n Alle 3 Monate den Schachtboden von Schlamm befreien und auch die Schachtw nde reinigen Ablagerungen am Schwimmschalter mit klarem Wasser entfernen Die Pumpe darf nicht vom Anwender ge ffnet werden T...

Страница 18: ...teilen Explosionszeich nungen und Informationen zu Ersatzteilen finden Sie auch unter www eco repa com Das ELEM PROFESSIONAL WATER PUMPS Anwendungsberatungs Team hilft Ihnen gerne bei Fragen zu unsere...

Страница 19: ...eviste per quell utilizzo con sezione di conduzione sufficiente La spina ed il collegamento del cavo prolunga utilizzato devono essere protetti dagli spruzzi d acqua Non utilizzare il cavo di allaccia...

Страница 20: ...L interruttore a galleggiante cos regolato da permettere un immediata messa in esercizio della pompa Avvertenza Il pozzetto della pompa deve avere almeno le dimensioni di 40 x 40 x 50 cm in modo tale...

Страница 21: ...sione di rete 220 240V Frequenza di rete 50 Hz Lunghezza del cavo elettrico 6m Potenza assorbita 0 75kW Velocit in assenza di carico 2850 min 1 Capacit massima della pompa 367l min Sollevamento massim...

Страница 22: ...IEGHI Il servizio di assistenza risponde alle Vostre domande relative alla riparazione ed alla manutenzione del Vostro prodotto nonch concernenti le parti di ricambio Disegni in vista esplosa ed infor...

Страница 23: ...23 PVG100 PGV150 PGV200...

Страница 24: ...erator When not in use store the machine out of reach of children This tool is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experi...

Страница 25: ...Montigny le Tilleul Belgique EC declaration of conformity ELEM PROFESSIONAL WATER PUMPS declares that the machines Submergible pump PVG100 have been designed in compliance with the following standards...

Страница 26: ...ens Pierre Direttore ELEM PROFESSIONAL WATER PUMPS rue de Goz e 81 6110 Montigny le Tilleul Belgique Declaraci n CE de conformidad ELEM PROFESSIONAL WATER PUMPS declara que las m quinas Bomba sumergib...

Страница 27: ...Montigny le Tilleul Belgique EC declaration of conformity ELEM PROFESSIONAL WATER PUMPS declares that the machines Submergible pump PVG150 have been designed in compliance with the following standards...

Страница 28: ...ens Pierre Direttore ELEM PROFESSIONAL WATER PUMPS rue de Goz e 81 6110 Montigny le Tilleul Belgique Declaraci n CE de conformidad ELEM PROFESSIONAL WATER PUMPS declara que las m quinas Bomba sumergib...

Страница 29: ...EEE Belgi December 2015 Mr Joostens Pierre Directeur ELEM PROFESSIONAL WATER PUMPS rue de Goz e 81 6110 Montigny le Tilleul Belgique EC declaration of conformity ELEM PROFESSIONAL WATER PUMPS declares...

Страница 30: ...ens Pierre Direttore ELEM PROFESSIONAL WATER PUMPS rue de Goz e 81 6110 Montigny le Tilleul Belgique Declaraci n CE de conformidad ELEM PROFESSIONAL WATER PUMPS declara que las m quinas Bomba sumergib...

Страница 31: ...5031 Abano Terme PD Italy Tel 39 049 8591796 Fax 39 049 2131357 Web address www elettromeccanicaabano it Head office SOGGIA s a s di Soggia Gabriele e C via Busonera 24 35031 Abano Terme PD Italy Tel...

Отзывы: