Group
Parameters & description
Analog interface REM-SB Action
Selects how the input pin REM-SB of the analog interface shall operate regarding the DC output con-
dition outside of analog remote control:
•
DC Off
= the pin can only switch the DC power stage off
•
DC On/Off
= the pin can switch the DC power stage off and on again, if it has been switched on before
from a different control location
Pin 6
Pin 6 of the analog interface (see section
3.5.4.3) is by default assigned to signal both device alarms OT
and PF. This parameter allows to also enable signaling only one of both (3 possible combinations):
•
Alarm OT
= Pin 6 signals only alarm OT
•
Alarm PF
= Pin 6 signals only alarm PF
•
Alarm PF + OT
= Default, pin 6 signals either PF or OT
Pin 14
Pin 14 of the analog interface (see section
3.5.4.3) is by default assigned to only signal the device alarm
OVP. This parameter allows to also enable signaling the device alarms OCP and OPP in 7 possible
combinations:
•
Alarm OVP
= Pin 14 signals only OVP
•
Alarm OCP
= Pin 14 signals only OCP
•
Alarm OPP
= Pin 14 signals only OPP
•
Alarm OVP+OCP
= Pin 14 signals OVP or OCP
•
Alarm OVP+OPP
= Pin 14 signals OVP or OPP
•
Alarm OCP+OPP
= Pin 14 signals OCP or OPP
•
Alarm OVP+OCP+OPP
= Pin 14 signals any of the three alarms
Pin 15
Pin 15 of the analog interface (see section
3.5.4.3) is by default assigned to signal the regulation mode
CV. Alternatively, it allows to signal the DC output status:
•
Regulation mode
= Signals the CV regulation mode
•
DC status
= Signals the DC output status
DC output
State after power ON
Determines the condition of the DC output after power-up.
•
Off
= DC output is always off after switching on the device.
•
Restore
= Default, DC output state will be restored from last switch-off.
The factory default of this setting, also after a device reset, is “Off”. Setting
this to “Restore” solely lies within the responsibility of the operator, as the
device could automatically start to supply voltage after boot-up, depending on
the restored state of the DC terminal. Be careful!
State after PF alarm
Determines the condition of the DC output after a power fail (PF) alarm:
•
Off
= Default, DC output remains off
•
Auto
= DC output will switch on again after the PF alarm cause is gone, if it has been switched on
before the alarm occurred
State after remote
Determines the condition of the DC output after leaving remote control either manually or by command:
•
Off
= Default, DC output will always be off after leaving remote control
•
Auto
= DC output will keep the last state