EDA-Z1000 - Installation and Operation Manual                                                                                                                  

 

 

Revision History 

 
 

Manual 
Version 

Author Software 

Version 

Date Description 

V1.00 DR  0.08  01-10-05 

First 

Release 

V1.01 DR  0.10  01-11-05 

Sounder Repeater Added to System, Access code override function and ability to view access codes, re-program 
devices to factory settings, re-program unique Id. Antenna monitoring configuration added. 

V1.02 

DR 

0.10 

22-12-05 

Must reset booster panel to ensure memory cleared. All other devices should also be reset on power up. Operation of 
fire relays when silence / reset pressed 

V1.03 SM  0.15  13-06-06 

New features for disabling faults and Double knock functions. 

V1.04 SM  1.01  14-03-07 

New menu structure, Survey mode, function keys and sounder circuit 

V1.05 

SM 

1.02 

18-02-08 

HMO software, antenna calibration option, add Text via the panel and contrast settings added 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 

    

Version Z1000/V1.05 

 

Electro-Detectors                      

Page 

3

 

   

Содержание EDA-Z1000

Страница 1: ...tem Operation Manual Electro Detectors Ltd Electro House Edinburgh Way Harlow Essex CM20 2EG UK Tel 01279 635668 Fax 01279 450185 Email eda electrodetectors co uk Web www electrodetectors co uk Electro Detectors Version Z1000 V1 05 ...

Страница 2: ...viceable parts are contained within this panel Always refer to a qualified technician for parts and servicing This manual should be provided to the site s nominated responsible person and left on the premises for easy reference Version Z1000 V1 05 Electro Detectors Page 2 ...

Страница 3: ...na monitoring configuration added V1 02 DR 0 10 22 12 05 Must reset booster panel to ensure memory cleared All other devices should also be reset on power up Operation of fire relays when silence reset pressed V1 03 SM 0 15 13 06 06 New features for disabling faults and Double knock functions V1 04 SM 1 01 14 03 07 New menu structure Survey mode function keys and sounder circuit V1 05 SM 1 02 18 0...

Страница 4: ...To Silence Sounders 3 7 To Re sound the Sounders 3 8 To Reset an Alarm 3 9 Menu Navigation 3 10 To Change Date and Time 3 11 To Isolate a Zone 3 12 To Isolate a Device 3 13 To Enable a Zone 3 14 To Enable a Device 3 15 View System History of Events 4 0 Advanced User Operations 4 1 General 4 2 To View Access Codes 4 3 Changing Access Codes 4 4 To Select a Test Mode 4 5 To Disable a Test Mode Versio...

Страница 5: ...uld the need arise In order to log devices and program devices into the system they need to be connected via a supplied programming lead The system also stores the data programmed into each device allowing replacement devices to be easily cloned onto the system Prior to installation the building where the system is to be installed must be surveyed to ensure that each device to be fitted has a good...

Страница 6: ...n the up and down arrow keys allow the user to scroll through all the current events The display will also scroll automatically every 6 seconds Keys Function 1 2 Programmable for use as Evacuate and Alert functions Cancel Used to return to the main screen from a menu or to return to the menu from a programming screen Enter This is used to accept information programmed into the panel Menu Press to ...

Страница 7: ...er Once the Silence buzzer button has been pressed the panel assumes that the fault has been acknowledged and does not resound the buzzer If a different fault occurs the panel will sound the buzzer until the new fault has been acknowledged 3 4 To Reset a Fault Assuming the fault has been rectified pressing reset will reset the system and the system normal screen will be displayed If the fault is s...

Страница 8: ...that occurred during the alarm condition 3 9 Menu Navigation To enter the menu system press MENU and enter a valid password Main Menu will appear To scroll through the menu the or keys should be pressed In order to select a menu option the key should be pressed To return to the previous menu screen from a sub menu the should be pressed Pressing Cancel will return to the system screen where any fau...

Страница 9: ...ther Disablement conditions such as isolated devices exist Select Zone 01 Press ENTER to enable Zone 01 ENTER to continue 3 14 To Enable a Device To enable a previously isolated device press MENU and enter a valid password Select 2 Disable Enable select 2 Enable select 2 Enable Device Using the or keys select the device number to be enabled and press ENTER To enable more devices press ENTER or CAN...

Страница 10: ...n re enter the new password to confirm Press ENTER to save the new password A message will be displayed indicating that the password is being saved to the SIM and flash memory Access Level 1 Enter Current Code Enter New Code Confirm New Code Basic User ENTER to continue Hold CANCEL to exit Hold CANCEL to exit Hold CANCEL to exit 4 3 To Select Test Mode Test mode is available to an advanced user so...

Страница 11: ... It can be set in 1 hour intervals and is selected using the cursor keys A maximum of 48 hours can be set The user should now press enter to enable the test mode The Test Mode LED will illuminate Test Mode Enabled Save Test Settings YES ENTER to Continue Once test options have been selected these can now be saved for quick setup in the future Once the test screen is entered the panel will prompt t...

Страница 12: ...EDA Z1000 Installation and Operation Manual Version Z1000 V1 05 Electro Detectors Page 12 ...