44
200 mm
650 mm
500 mm
450 mm
Fig. 8.2a
■
Class 1
Gas connection
made using rubber
hose which must be
visible and easily
inspected or using
rigid or flexible metal
pipe.
88
INSTALLATION
LOCATION
The appliance must be kept no less than 50 mm away from any side wall which exceed
the height of the hob surface (fig. 8.2a - 8.2b).
The appliance must be housed in heat resistant units.
The walls of the units must be capable of resisting temperatures of 75 °C above
room temperature.
Do not install the appliance near inflammable materials (eg. curtains).
If the cooker is located on a pedestal it is necessary to provide safety measures to pre-
vent falling out.
Before installing the cooker level the appliance by screwing or unscrewing the six
adjustable feet fitted below.
WARNING!
For safety reasons unscrew
the feet (from screwed posi-
tion) to the maximum extent of
5 mm (fig. 8.1).
Fig. 8.1