48
99
GAS SECTION
GASES
Cat:
II
2H3+
The gases used for the operation of
cooking appliances may be grouped by
their characteristics into two types:
✓
G 20
20 mbar
✓
G 30/ G31 28-30/37 mbar
GB
The walls adjacent to the cooker
must be of material resistant to heat.
Before installation, make sure that
the local distribution conditions
(type of gas and its pressure) and
the adjustment of this appliance
are compatible. The appliance
adjustment conditions are given on
the plate or the label.
GAS CONNECTION
The connection must be executed by a
qualified technician according to the rel-
evant standards.
The appliance is predisposed and cali-
brated to operate with the gas indicated
on the specifications plate.
Ensure that the room in which the cook-
er is to be installed is adequately venti-
lated, in compliance with applicable reg-
ulations.
Connection to the gas supply pipe or
gas cylinder must be made in accor-
dance with the requirements of the
applicable regulations.
Fig. 9.1b
Fig. 9.1a
gas pipe
cooker
rear protection
The gas supply must be connected to
the gas inlet which is located at the rear
of the appliance as illustrated in the
figures 9.1a or 9.1b.
If the connection pipe cross the cooker,
it must be positioned under the cooker
rear protection (fig. 9.1a).