TECHNICAL SHEET : SAFETY REPORT OF BIG ONE X-TREME
2/5
I
ELECTRICAL SAFETY
THIS PART DESCRIBES COMPONENT AND DESIGN PROPERTIES RESULTING IN AN ELECTRIC SHOCK SAFE
AND ENERGY SAFE DEVICE
I.1
ELECTRICAL CLASSIFICATION
According to the standard, this device is classified as CLASS I equipment : electric safety is obtained by use of protective earth.
This device should therefore be earthed! It is connected to the mains power with a detachable power supply cord (pluggable
type A.) in the bottom left side. The cable can be fixed undetachable by suitable means.
I.2
SPECIFICATIONS
BIG ONE X-TREME
Rated voltage
115 / 230V
frequentie (Hz)
47-63 Hz
@230VAC
@115VAC
Overload protection
4A
6.3A
by slo blo 20x5mm fuse
Rated current (I)
2.2A
4.4A
Consumption (W) nom. 312W
Consumption (W) max. 512W
Consumption (W) stby. W
refer to ‘BO_xtreme_fuses’ file
for details
I.3
BASE ELECTRICAL CONCEPT
The Big One X-treme is an amusement machine consisting of
-
an assembly of aluminium frame cabinet panels with chipwood plate and glas panels, inaccessably closed for non
authorized personel. The inside of the machine can be accessed by means of a key-locked door. Technical comparments
are then accessed again with a key locked panel.
-
containing mains connected :
•
bottom mains entry box
•
control cabinet containing Intelli supply unit ext (game electronics supply) and RGB light and audio supply unit
•
top mains RGB light supply
•
43” monitor
•
2 led spotlights
-
low voltage powered :
•
4 top sign lighting units
•
4 sides RGB lighting units
•
a player’s section with controls, displays, speakers, optional ticket dispenser, coin- and bill acceptor
•
an automated prize box
•
moving gantry in the cabinet
I.4
ELECTRICAL SCHEMATIC
refer to ‘BO_xtreme_primary_schematic' file.
I.5
ELECTRICAL PROPERTIES OF COMPONENTS
The machine is standardly configured to be connected to the mains power by means of a standard power cord to the mains entry
connector in the bottom. This entry plate contains entry connector, fuse and switch.
Wiring with a section of 0.75 mm² is used for mains wiring.
The earth conductor is connected to this units, to the blank plate, and is connected to the cabinet's frame.
Содержание Big One X-treme
Страница 28: ...Building X treme Big One 23 Document versie V1 1...
Страница 61: ...2...
Страница 63: ...4...
Страница 80: ...21...
Страница 85: ...technical file Big One X treme 1 MANUAL 2 CABINETS 3 PRIMARY CIRCUITS 4 ELECTRONICS 5 FUNCTIONALITY 6 WIRING...
Страница 87: ...technical file Big One X treme 1 MANUAL 2 CABINETS 3 PRIMARY CIRCUITS 4 ELECTRONICS 5 FUNCTIONALITY 6 WIRING...
Страница 107: ...missing txt datasheet missing Pagina 1...
Страница 109: ...technical file Big One X treme 1 MANUAL 2 CABINETS 3 PRIMARY CIRCUITS 4 ELECTRONICS 5 FUNCTIONALITY 6 WIRING...
Страница 112: ...technical file Big One X treme 1 MANUAL 2 CABINETS 3 PRIMARY CIRCUITS 4 ELECTRONICS 5 FUNCTIONALITY 6 WIRING...
Страница 113: ...refer to machine manual...
Страница 114: ...technical file Big One X treme 1 MANUAL 2 CABINETS 3 PRIMARY CIRCUITS 4 ELECTRONICS 5 FUNCTIONALITY 6 WIRING...
Страница 127: ...Refer to digital version for part datasheets...