MEMORY STORAGE
Up to 1 million vehicles
FORMAT
Charts and graphs in Excel and/or Pdf form, for easy report
printing
POWER OPTIONS
“SOLAR” (solar-powered)
Internal solar regulator, solar panel, 2 batteries
“AC” (mains or street light) 230V AC with internal charger, 1 battery (capacity for 2)
“AC MOBILE” (battery
operated)
4 batteries (2 inside casing) + external charger and 230V AC
with internal charger
ACCESSORIES
MOUNTING KITS
Curved, ABS-injected resin, universal mounting-bar;
aluminum bracket (for solar)
SOLAR PANEL
32” X 27”, 80 watt solar panel
BATTERIES
12V/22AH batteries included: 1(AC pack), 2(Solar pack),
4(AC Mobile pack)
EXTERNAL CHARGER
12V external charger (included in AC Mobile pack)
9
IF THE EVOLIS DOESN’T WORK
Before making contact with Elancity after sales service please refer to the following chart of
symptoms / solutions. If this doesn’t provide the solution and you are still experiencing
problems please contact our Tech Team for assistance:
•
Tools / equipment required:
Symptoms
Potential causes
Parts concerned
No display
Power supply
Batteries / Plugs / Solar
panel
Solutions :
1. Turn the dial switch to ‘Off’ then to ‘SP’ and check the auto test of both displays: speed
and messages. (for an auto test – click on the green tick)
2. Try a connection on Evocom either via USB or Bluetooth.
3. Check if the spy mode is activated on Evocom. If yes, disactivate it on the Evocom settings
page
4. Control the power supply to the Evolis by checking the voltage at the battery terminals, at
the solar panel and at the mains supply 220V.
5. Check the primary fuse located in the battery compartment. It is situated just to the left of
the control dial inside the radar casing.
6. Check the condition of the external plugs.