INSTALLATION REQUIREMENTS

This appliance MUST NOT be installed into a room containing a bath or shower, or where steam
may be present. The fire has been designed to fit into a builders’ opening or fireplace conform-
ing to BS 1251 (and meeting certain dimensional requirements), or a suitable flue box complying
with the constructional requirements of BS 715. The flue box must be installed onto a suitable
non-combustible insulating surface at least 12mm thick, covering the entire base area of the box.

The flue must have an effective height of at least three meters, as measured from the hearth to
the top of the flue. Any flue damper plates or restrictors should be removed and no other restric-
tion fitted to the flue. Where removal is not practical, the restriction must be fixed in the fully
open position.

A natural draught flue system is required, and if previously used for solid fuel or oil burning, the
flue and chimney must be swept prior to appliance installation. The flue must be checked before
installation by using a smoke pellet or similar to ensure proper draw and that leakage is not evi-
dent at any joints. Repair and re-test as necessary before the appliance is installed.

The flue must be connected to only one fireplace, and the flue must not vent more than one appli-
ance (i.e. not shared with a gas back boiler). There must be no opening in the flue apart from the
one that the appliance is installed into, and the one venting the gases into the air. A suitable ter-
minal may be fitted, such as class GC1, as regulations allow.

This appliance is suitable for use with a “lightweight” surround and back panel of 150ºC minimum
rating.

SITE REQUIREMENTS

The fireplace opening should be inspected and repairs made where necessary. Any chair brick or
fireback may be left in place, providing that the dimensional requirements for debris collection
and spigot clearance are met.

The opening WIDTH and HEIGHT dimensions should be between 400mm and 460mm wide, and
540mm to 570mm high.

Opening DEPTH should be 210mm or greater. Opening DEPTHS include any plaster or infill pan-
els which form part of the installation.

2

APPLIANCE DATA

Manual Control Version

Remote Control Version

Gas Group

G20 Natural Gas CAT I2H

G20 Natural Gas CAT I2H

Inlet Pressure

20mbar (+/- 2.0mbar)

20mbar (+/- 2.0mbar)

Max Energy Input (gross)

6.8kW

6.8kW

Min Energy Input (gross)

3.5kW

3.5kW

Pilot Energy Input (gross)

166W

166W

Setting Pressure (cold)

15.8mbar (+/- 1.5mbar)

15.8mbar (+/- 1.5mbar)

Main Injector Burner

Stereo 81/Bray cat. 82/420

Stereo 81/Bray cat. 82/420

Gas Inlet Connection

8mm Inlet Restrictor Elbow

8mm Inlet Restrictor Elbow

Gas Control Valve

Dungs BM 733/NGC 6802

Mertik Maxitrol GV34 Series

Ignition

Integral Piezo spark

Integral Piezo spark

Spark Gap

3.5 to 4.5mm

3.5 to 4.5mm

Weight

20 Kg

22 Kg

Please see Data Badge affixed to appliance for current data.

This appliance is for use only with the gas type, and at the pressure stated on the appli-

ance Data Badge, and is for decorative purposes.

2.0

3.0

4.0

©

2009 Focal Point Fires plc.

Содержание eko 2010

Страница 1: ...installation and user instructions All instructions must be handed to user for safekeeping Revision A 06 09 Country s of destination GB IE eko 2010 eko 2020 fuel effect gas fire...

Страница 2: ...ppliance is factory set for operation on the gas type and at the pressure stated on the appli ance data plate This appliance is available in either a manual control version or a battery powered remote...

Страница 3: ...is appliance features a battery opearated remote control system and under normal usage will need new batteries approximately every twelve months Remote control Handset requirements 1 x PP3 type 9 volt...

Страница 4: ...is installed into and the one venting the gases into the air A suitable ter minal may be fitted such as class GC1 as regulations allow This appliance is suitable for use with a lightweight surround an...

Страница 5: ...e providing that it complies with the dimensions given below A non combustible shelf may be fitted to within 10mm of the top edge of the fireframe Combustible materials such as wood may be fitted to w...

Страница 6: ...s appliance can be fitted into a number of proprietory flue boxes provided that the minimum dimensions given in the diagram below are complied with The flue outlet of the fire must not obscure the flu...

Страница 7: ...x PP3 4 x AA remote control option only 1 Self tapping screw pack 3 Lengths of self adhesive sealing strip 1 Rubber grommet PREPARING THE APPLIANCE Note Ensure that the gas supply is isolated before...

Страница 8: ...ot outlet of the firebox is not restricted in any way Remove the firebox and take any necessary measurements before making good and prepar ing for final installation CABLE FIXING For fixing of the fir...

Страница 9: ...ayout given the eyebolts should be posi tioned as close to the correct layout as possible Before finally fitting cables ensure the self adhesive sealing strips are in position on the back of the appli...

Страница 10: ...plate is not already fitted attach with two screws ensuring the control knob is free to be depressed fully FUEL BED LAYOUT Coal Effect Option 1 Remove the combustion matrix from its pro tective packag...

Страница 11: ...ain remember not to push the coals down too far into the valleys between the coal supports as this can have a detri mental effect to the flame picture 5 Now take another six coals and place behind the...

Страница 12: ...o be taken not to push the pebbles right down between the supports as this can affect the flame picture when the appliance is running 3 Take five more ceramic pebbles and posi tion as shown to form th...

Страница 13: ...inishes The frame is of three piece design and is held onto the firebox by magnets Firstly attach two magnets one at the top and one at the bot tom to each side piece and then attach to the sides of t...

Страница 14: ...e control versions The gas valve has two control knobs Turn the main burner control shown on left hand side of control valve knob fully anti clockwise Turn ignition knob shown on right hand side of co...

Страница 15: ...pressure is acceptable then a problem in the supply pipework is to be suspected This will be dirt and debris kinked or inadequate size pipes restriction in a fitting or solder flashing across a joint...

Страница 16: ...r servicing Frequency of service depends on usage but MUST be carried out at least one annually Scratched and other superficial damage to the matt black paintwork of the appliance can be cov ered with...

Страница 17: ...g further Check the seal around the fire frame and replace if necessary Refitting of the firebox is described in the relevant section DISMANTLING THE BURNER TRAY Remove the tray as previously describe...

Страница 18: ...and then cuts off Excessive room draught or flue pull rectify Loose or faulty thermocouple rectify ODS system in operation Firebox grommet seal not fitted rectify Lint in pilot aeration hole clean th...

Страница 19: ...foreign material on this fire the fuel effect must be of the correct type and laid out in accordance with the relevant section of these instructions Failure to do so could create a hazard or lead to s...

Страница 20: ...t by your CORGI registered installer For Republic of Ireland ventilation may be required see IS 813 ICP3 IS 327 and any other rules in force OPERATING INSTRUCTIONS manual versions The pilot is visible...

Страница 21: ...n inbuilt safety feature to pre vent the main burner being activated or turned up accidentally It is nec essary to press button 1 and 2 see illustration simultaneously to turn the fire up To turn the...

Страница 22: ...COALS AND CERAMICS See the relevant section in the Installation Guide of these instructions Do not create dust from the coals Clean gently in the open air Replace components with original spares only...

Отзывы: