background image

FUEL BED LAYOUT  -  continued

5. Finally, take the six remaining pebbles and
place at the back of the fuel matrix as shown. 
Once again, the pebbles may be orientated as
desired in order to give a realistic effect. Avoid
pushing the pebbles down between the sup-
ports. The fuel bed layout is now complete.  

The fire is designed to operate correctly with the pebbles supplied when assembled according to
the instructions. Never add to the twenty-two pebbles, or change them for a different type. Never
throw rubbish or other matter onto the fuel bed. 

Due to the light colour of the pebbles, some discolouration/sooting is to be expected during nor-
mal use. 

INSTALLING THE BATTERIES (remote control versions only)

Handset - Remove cover from rear of handset and insert 1 x ‘PP3’ (9 volt) battery - Replace cover

Appliance - 

Ensure appliance is off and cool

. Remove cover from top of receiver box. The cover

is protected by reflective foil, and located towards the right hand side, underneath the burner
unit. Insert 4 x ‘AA’ (1.5 volt) batteries - Replace cover.

FITTING THE DECORATIVE FRAME AND FRONT

The appliance is supplied with a decorative frame in a variety of
finishes. The frame is of three-piece design and is held onto the
firebox by magnets

Firstly attach two magnets (one at the top and one at the bot-
tom) to each side piece and then attach to the sides of the fire-
box frame. Attach the remaining two magnets to the top piece
and position on the top of the firebox frame ensuring the cor-
ners meet neatly.

IMPORTANT : Due to the possibility of sharp edges, care
should be taken when handling the three-piece frame com-
ponents. The use of protective gloves is recommended.

Place the decorative firefront in front of the fire and slide the
ashpan door into place. The firefront shown in these instructions may be different to the one sup-
plied with the appliance.

Eko 2020 models :

The firefront is retained in position on the firebox by two bracket as shown.

Position the firefront so the holes in the retaining brackets line up with the M6 inserts in the fire-
box. Secure the front in position using the two M6 screws provided.

TESTING AND COMMISSIONING

Turn on and test the gas supply up to the fire for any leaks, in accordance with current edition of
BS6891.

When the appliance is first used, protective oils coating the firebox may burn off. It is advisable
to ventilate the room during this period for at least one hour.

11

13.0

12.1

14.0

12.2

Eko 2020 Front location

©

2009 Focal Point Fires plc.

Содержание eko 2010

Страница 1: ...installation and user instructions All instructions must be handed to user for safekeeping Revision A 06 09 Country s of destination GB IE eko 2010 eko 2020 fuel effect gas fire...

Страница 2: ...ppliance is factory set for operation on the gas type and at the pressure stated on the appli ance data plate This appliance is available in either a manual control version or a battery powered remote...

Страница 3: ...is appliance features a battery opearated remote control system and under normal usage will need new batteries approximately every twelve months Remote control Handset requirements 1 x PP3 type 9 volt...

Страница 4: ...is installed into and the one venting the gases into the air A suitable ter minal may be fitted such as class GC1 as regulations allow This appliance is suitable for use with a lightweight surround an...

Страница 5: ...e providing that it complies with the dimensions given below A non combustible shelf may be fitted to within 10mm of the top edge of the fireframe Combustible materials such as wood may be fitted to w...

Страница 6: ...s appliance can be fitted into a number of proprietory flue boxes provided that the minimum dimensions given in the diagram below are complied with The flue outlet of the fire must not obscure the flu...

Страница 7: ...x PP3 4 x AA remote control option only 1 Self tapping screw pack 3 Lengths of self adhesive sealing strip 1 Rubber grommet PREPARING THE APPLIANCE Note Ensure that the gas supply is isolated before...

Страница 8: ...ot outlet of the firebox is not restricted in any way Remove the firebox and take any necessary measurements before making good and prepar ing for final installation CABLE FIXING For fixing of the fir...

Страница 9: ...ayout given the eyebolts should be posi tioned as close to the correct layout as possible Before finally fitting cables ensure the self adhesive sealing strips are in position on the back of the appli...

Страница 10: ...plate is not already fitted attach with two screws ensuring the control knob is free to be depressed fully FUEL BED LAYOUT Coal Effect Option 1 Remove the combustion matrix from its pro tective packag...

Страница 11: ...ain remember not to push the coals down too far into the valleys between the coal supports as this can have a detri mental effect to the flame picture 5 Now take another six coals and place behind the...

Страница 12: ...o be taken not to push the pebbles right down between the supports as this can affect the flame picture when the appliance is running 3 Take five more ceramic pebbles and posi tion as shown to form th...

Страница 13: ...inishes The frame is of three piece design and is held onto the firebox by magnets Firstly attach two magnets one at the top and one at the bot tom to each side piece and then attach to the sides of t...

Страница 14: ...e control versions The gas valve has two control knobs Turn the main burner control shown on left hand side of control valve knob fully anti clockwise Turn ignition knob shown on right hand side of co...

Страница 15: ...pressure is acceptable then a problem in the supply pipework is to be suspected This will be dirt and debris kinked or inadequate size pipes restriction in a fitting or solder flashing across a joint...

Страница 16: ...r servicing Frequency of service depends on usage but MUST be carried out at least one annually Scratched and other superficial damage to the matt black paintwork of the appliance can be cov ered with...

Страница 17: ...g further Check the seal around the fire frame and replace if necessary Refitting of the firebox is described in the relevant section DISMANTLING THE BURNER TRAY Remove the tray as previously describe...

Страница 18: ...and then cuts off Excessive room draught or flue pull rectify Loose or faulty thermocouple rectify ODS system in operation Firebox grommet seal not fitted rectify Lint in pilot aeration hole clean th...

Страница 19: ...foreign material on this fire the fuel effect must be of the correct type and laid out in accordance with the relevant section of these instructions Failure to do so could create a hazard or lead to s...

Страница 20: ...t by your CORGI registered installer For Republic of Ireland ventilation may be required see IS 813 ICP3 IS 327 and any other rules in force OPERATING INSTRUCTIONS manual versions The pilot is visible...

Страница 21: ...n inbuilt safety feature to pre vent the main burner being activated or turned up accidentally It is nec essary to press button 1 and 2 see illustration simultaneously to turn the fire up To turn the...

Страница 22: ...COALS AND CERAMICS See the relevant section in the Installation Guide of these instructions Do not create dust from the coals Clean gently in the open air Replace components with original spares only...

Отзывы: