USER INSTRUCTIONS

IMPORTANT NOTES

The installation of this fire MUST only be carried out by a competent

[1]

person in accordance with

the Gas Safety (Installation and Use) Regulations 1998, the relevant British Standards, Codes of
Practice, the Building Regulations and the manufacturers’ instructions.Failure to comply with the
above recommendations could lead to prosecution and invalidate the appliance warranty.

Please ensure you are handed all of the manufacturers documents on completion of the installa-
tion. This will include these instructions.
Always keep a note of the installer’s name and address, the original purchase receipt and the date
of installation for future reference.

The fire and flue should be serviced regularly to ensure continued safe operation. See the servic-
ing section for further details. Frequency of service will depend on use, but MUST be carried out
at least once annually.

Parts of this appliance become naturally hot during use. It is recommended that a suitable fire
guard conforming to BS 8423 : 2002 is used, especially where young children, the elderly, or
infirm are concerned.

Combustible items, such as flooring and furniture, and soft wall coverings (such as blown vinyl
or embossed paper) may discolour if fitted too close to the fire. See relevant section for further
details on clearances to combustibles. No combustible material or flooring should protrude onto
the hearth.

DO NOT burn any foreign material on this fire, the fuel effect must be of the correct type and laid
out in accordance with the relevant section of these instructions. Failure to do so could create a
hazard or lead to sooting.

Before the appliance is installed, the chimney should be swept. All flues should be checked by the
installer to ensure there are no defects or obstructions that may prevent the flow of combustion
products.
This appliance is fitted with a flue blockage safety device which will shut down the fire if abnor-
mal flue conditions occur. It is NOT a substitute for an independently mounted Carbon Monoxide
detector.
The fire is only suitable for use with the gas type for which it is supplied.

Remote control models only -

This appliance features a battery-opearated remote control sys-

tem. Remote control models, under normal usage will need new batteries approximately every
twelve months.

Remote control Handset requirements - 1 x ‘PP3’ type (9 volt)
Reciever/motor unit  requirements - 4 x ‘AA’ type (1.5 volt) 

Refer to the appropriate section of these instructions for details of how to change the batteries.

1

Section

1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0

Contents

Important Notes
Firefront
Clearances to Combustibles
Ventilation
Operating Instructions
Replacing the batteries (remote control versions only)
Flue Spillage Monitoring System
Cleaning
List of Spares

Page No.

1
2
2
2
2
3
3
3
4

1.0

©

2009 Focal Point Fires plc.

[1] GB - Gas Safe

TM

registered operatives (Northern Ireland only- CORGI registered operatives) are the only class of person considered as competent by the HSE under the Gas Safety (Installation and Use)

Regulations 1998.

Содержание eko 2010

Страница 1: ...installation and user instructions All instructions must be handed to user for safekeeping Revision A 06 09 Country s of destination GB IE eko 2010 eko 2020 fuel effect gas fire...

Страница 2: ...ppliance is factory set for operation on the gas type and at the pressure stated on the appli ance data plate This appliance is available in either a manual control version or a battery powered remote...

Страница 3: ...is appliance features a battery opearated remote control system and under normal usage will need new batteries approximately every twelve months Remote control Handset requirements 1 x PP3 type 9 volt...

Страница 4: ...is installed into and the one venting the gases into the air A suitable ter minal may be fitted such as class GC1 as regulations allow This appliance is suitable for use with a lightweight surround an...

Страница 5: ...e providing that it complies with the dimensions given below A non combustible shelf may be fitted to within 10mm of the top edge of the fireframe Combustible materials such as wood may be fitted to w...

Страница 6: ...s appliance can be fitted into a number of proprietory flue boxes provided that the minimum dimensions given in the diagram below are complied with The flue outlet of the fire must not obscure the flu...

Страница 7: ...x PP3 4 x AA remote control option only 1 Self tapping screw pack 3 Lengths of self adhesive sealing strip 1 Rubber grommet PREPARING THE APPLIANCE Note Ensure that the gas supply is isolated before...

Страница 8: ...ot outlet of the firebox is not restricted in any way Remove the firebox and take any necessary measurements before making good and prepar ing for final installation CABLE FIXING For fixing of the fir...

Страница 9: ...ayout given the eyebolts should be posi tioned as close to the correct layout as possible Before finally fitting cables ensure the self adhesive sealing strips are in position on the back of the appli...

Страница 10: ...plate is not already fitted attach with two screws ensuring the control knob is free to be depressed fully FUEL BED LAYOUT Coal Effect Option 1 Remove the combustion matrix from its pro tective packag...

Страница 11: ...ain remember not to push the coals down too far into the valleys between the coal supports as this can have a detri mental effect to the flame picture 5 Now take another six coals and place behind the...

Страница 12: ...o be taken not to push the pebbles right down between the supports as this can affect the flame picture when the appliance is running 3 Take five more ceramic pebbles and posi tion as shown to form th...

Страница 13: ...inishes The frame is of three piece design and is held onto the firebox by magnets Firstly attach two magnets one at the top and one at the bot tom to each side piece and then attach to the sides of t...

Страница 14: ...e control versions The gas valve has two control knobs Turn the main burner control shown on left hand side of control valve knob fully anti clockwise Turn ignition knob shown on right hand side of co...

Страница 15: ...pressure is acceptable then a problem in the supply pipework is to be suspected This will be dirt and debris kinked or inadequate size pipes restriction in a fitting or solder flashing across a joint...

Страница 16: ...r servicing Frequency of service depends on usage but MUST be carried out at least one annually Scratched and other superficial damage to the matt black paintwork of the appliance can be cov ered with...

Страница 17: ...g further Check the seal around the fire frame and replace if necessary Refitting of the firebox is described in the relevant section DISMANTLING THE BURNER TRAY Remove the tray as previously describe...

Страница 18: ...and then cuts off Excessive room draught or flue pull rectify Loose or faulty thermocouple rectify ODS system in operation Firebox grommet seal not fitted rectify Lint in pilot aeration hole clean th...

Страница 19: ...foreign material on this fire the fuel effect must be of the correct type and laid out in accordance with the relevant section of these instructions Failure to do so could create a hazard or lead to s...

Страница 20: ...t by your CORGI registered installer For Republic of Ireland ventilation may be required see IS 813 ICP3 IS 327 and any other rules in force OPERATING INSTRUCTIONS manual versions The pilot is visible...

Страница 21: ...n inbuilt safety feature to pre vent the main burner being activated or turned up accidentally It is nec essary to press button 1 and 2 see illustration simultaneously to turn the fire up To turn the...

Страница 22: ...COALS AND CERAMICS See the relevant section in the Installation Guide of these instructions Do not create dust from the coals Clean gently in the open air Replace components with original spares only...