PV Blocks system
Page 40
In this page the IV-curve measurements can be configured.
Between the start and stop time the IV-curves are measured at the interval time set each
day.
Between the measurement the PV-Module can be in one of the three states indicated by
Mode:
a.
kept in maximum power point (MPPT) by means of the Perturbation and observa-
tion (P&O) algorithm.
b.
kept in open voltage conditions
c.
kept at a fixed voltage bias which is set in the Voltage bias input box
The default scheduler will measure current and voltage pairs of ever Load at 1 mi-
nute intervals. Depending on the mode set, this will be MPP, Voc or Vbias
2.4.3.5. HARDWARE SETUP