Function
Settings
Description
Ta
rge
t Se
ttin
gs
White
Point
Temperature
4000 K to
10000 K
User
D50
D65
D65 (CRT)
DCI-P3
Set the White Point that will be used as a calibration target for
SelfCalibration.
Set the White Point using the color coordinates (White(x) /
White(y)) or color temperature.
When specifying color coordinates, set the values for "White(x)"
and "White(y)", respectively.
When specifying the color temperature, set the color
temperature in units of 100 K or select a color temperature
according to each standard.
Note
•
When color coordinates are specified, the color temperature
is changed to "User".
White(x) /
White(y)
0.2400 to
0.4500
Gamma
(EOTF)
Gamma
(EOTF)
1.0 to 2.7
sRGB
EBU(2.35)
L*
PQ
HLG
Fixed
Set the gamma that will be used as a calibration target for
SelfCalibration.
Set the gamma, or select the gamma curve defined by each
standard.
Note
•
The "Gamma (EOTF)" becomes "Fixed" when adjusting with
ColorNavigator 7.
Gamma
Policy
Standard
Gray Balance
Fixed Gamma
Select the gamma adjustment method for SelfCalibration.
• "Standard"
Adjust the gray balance while retaining the contrast.
•
"Gray Balance"
Adjust the monitor so that the chromaticity of the middle
tone area equals the white point.
•
"Fixed Gamma"
Select to use specific gamma settings.
Attention
•
If "HLG" is specified for "Gamma (EOTF)", "Fixed Gamma" is
selected and this setting cannot be changed.
•
With "Gray Balance", all points of the grayscale are adjusted
toward the target white point. Select this to prioritize whiteness
when correcting the middle tone area. However, the following
restrictions apply when "Gray Balance" is selected:
-
The contrast may decrease.
- The color gamut may be narrower than when adjusting with
"Fixed Gamma".
PQ Option
300cd/m
2
Clipping
500cd/m
2
Clipping
1000cd/m
2
Clipping
4000cd/m
2
Emulation
10000cd/m
2
Emulation
Set the PQ Option that will be used as a calibration target for
SelfCalibration.
Note
•
This can be set when "PQ" is specified for "Gamma (EOTF)".
HLG System
Gamma
1.0 to 1.5
Set the HLG system gamma that will be used as a calibration
target for SelfCalibration.
Note
•
This can be set when "HLG" is specified for "Gamma (EOTF)".
25
Chapter 3 Advanced Adjustments/Settings