Automatic Dust Compensation.

The Alarm monitors the contamination build-up in the chamber and then slowly compensates 

for it over an extended period - this is to ensure that a slow burning smouldering fire over a 

long period is not confused with dust build-up.
If the contamination has occurred quickly (e.g. due to dust from carpets being replaced) 

remove the Alarm from the ceiling, leave it disconnected for 5 minutes, then reinstall the 

Alarm (the air must be clean i.e. dust and smoke free). The dust compensation will now 

operate quickly within 45 seconds.

Other than the cleaning described above, no other customer servicing of this product is required.  

Servicing/repairs, when needed, must be performed by the manufacturer.
All Alarms are prone to dust and insect ingress which can cause false alarms or failure to alarm.
The latest design, materials and manufacturing techniques have been used in the construction of our 

Alarms to minimize the effects of contamination. However it is impossible to completely eliminate the 

effect of dust and insect contamination, and therefore, to prolong the life of the Alarm you must ensure 

that it is kept clean so that excess dust does not build up. Any insects or cobwebs in the vicinity of the 

Alarm should be promptly removed.
In certain circumstances even with regular cleaning, contamination can build up in the smoke sensing 

chamber causing the Alarm to sound or fail. If this happens the Alarm must be returned to us for servicing 

or replacement. Contamination is beyond our control, it is totally unpredictable and is considered normal 

wear and tear.
For this reason, contamination is not covered by the guarantee.

Содержание Ei2110e Series

Страница 1: ...Ei2110e Series Instruction Manual MULTI SENSOR FIRE ALARM with Rechargeable Lithium Cell Back up 230V INSTALLER Section P N B18397 Rev1...

Страница 2: ...1 INSTALLATION GUIDE 1 2 ALARM REMOVAL 2 HOW MANY ALARMS TO INSTALL 2 1 LD SYSTEMS 2 2 SELECTING ALARM TYPE 2 3 GRADE D SYSTEM 3 POSITIONING ALARMS 3 1 LOCATIONS TO AVOID 4 INSTALLATION 4 1 MOUNTING W...

Страница 3: ...NITS WILL BE DAMAGED DO NOT FIT ACTUAL ALARMS UNTIL ALL BUILDING WORK IS COMPLETED TO AVOID CONTAMINATION AFTER CHECKING OPERATION COVER ALARMS WITH DUST COVER UNTIL REQUIRED FOR USE HIGH VOLTAGE INSU...

Страница 4: ...4...

Страница 5: ...5...

Страница 6: ...ere follows the guidance in British Standard BS 5839 Part 6 2013 in general for further information see the BS standard itself The main reason for fitting Alarms in dwellings is to ensure that when th...

Страница 7: ...probabilities fire occurring injury or death to occupant system operating correctly with a fire early detection and warning to occupants in the event of a fire The greater the risks the more comprehen...

Страница 8: ...s in all rooms or areas that present a high fire risk to occupants Heat Alarms located in Heat Alarms must be within 5 3m of potential fire sources each Kitchen Smoke or Heat Alarms located in each Li...

Страница 9: ...i Sensor Fire Alarm Heat Alarm Bedrooms Shower Bathroom Kitchens Living Rooms Fire Response Slow Smouldering Fires polyurethane foam ignited bedding etc Nuisance Alarm Immunity Steam Condensation Dust...

Страница 10: ...nsor to these types of fires 4 Do not install in kitchens Improved Audibility The effectiveness of a Category LD2 system can be significantly enhanced if an additional Alarm interconnected is installe...

Страница 11: ...om walls See Figure 1 At least 300mm from any light fitting or decorative object which might obstruct smoke heat entering the Alarm Note Ceiling mounting is recommended do not wall mount Alarms Slopin...

Страница 12: ...oom e g attic hatches Temperature differences might stop smoke or heat from reaching the Alarm Next to or directly above heaters or air conditioning vents windows wall vents etc that can change the di...

Страница 13: ...UPS etc This product is designed to be connected to a Pure or True Sine Wave 230 Vac supply If connecting to a power source that utilises an inverter e g PV solar panel the Total Harmonic Distortion T...

Страница 14: ...ered 24 hours a day so it is important that it is not on a circuit that can be turned off by a switch Note BS 5839 6 2013 gives the following recommendations regarding the mains supply to be used in a...

Страница 15: ...house wires coloured blue or marked N IC Interconnect see Section 4 2 Figure 6 for information on interconnection Note Wiring must be installed in compliance with local regulations Warning Mixing the...

Страница 16: ...marked is provided for the convenience of the installer so that any copper Earth wire or cable coloured green yellow can be safely terminated To interconnect Alarms connect all the IC terminals toget...

Страница 17: ...recessed wiring ensure the rear gasket seals around the edge of the hole in the ceiling or wall This is to prevent air draughts affecting the smoke heat entering the Alarm If the hole is too large or...

Страница 18: ...The Ei2110e Multi Sensor Fire Alarm can also be RF interconnected to other RF devices by installing an Ei100MRF RadioLINK Module See the User manual for the Ei100MRF for further details on RF intercon...

Страница 19: ...above or to any other model produced by another manufacturer Doing so may damage the Alarms and could result in a shock or fire hazard Wiring must be installed in compliance with local regulations In...

Страница 20: ...it If they are connected between different units there may be excessive nuisance alarms Everybody may not be aware that they are being tested or that it is a nuisance alarm caused by cooking etc Ensur...

Страница 21: ...n and installation Read and retain carefully If you are just installing this unit this leaflet MUST be given to the householder Ei2110e Series Instruction Manual MULTI SENSOR FIRE ALARM with Rechargea...

Страница 22: ...MARY 4 MULTI SENSOR FIRE ALARM FEATURES 5 TESTING MAINTAINING YOUR ALARM 6 CLEANING YOUR ALARM 7 ALARM MEMORY 8 IMPORTANT SAFEGUARDS 9 PLANNING YOUR ESCAPE ROUTE 10 GETTING YOUR ALARM SERVICED 11 5 YE...

Страница 23: ...3 1 REGULAR CHECKS Look for Constant green light Red light flash every 40 sec Press test button for 10 sec Alarm will sound loudly Vacuum around side vents to clean...

Страница 24: ...s on If the Alarm beeps and the yellow light flashes at the same time the battery is depleted ensure green mains power light is on N B If the cause of an alarm is uncertain then it should be deemed to...

Страница 25: ...pidly All the other interconnected Alarms should sound If a nuisance alarm occurs press the Test Hush button to silence the Alarm for 10 minutes Clean your Alarm regularly This will reduce the risk of...

Страница 26: ...lashes every 48 Sec 2 Beeps with Flash Predict Low Battery Press Hold Button Off 1 Flash 1 Beep Predict Faulty Sensor Press Hold Button Off 2 Flashes 2 Beeps Predict End of Life EOL Press Hold Button...

Страница 27: ...pared with normal optical sensor Alarms 3 Increased Longevity and Ruggedness The Ei2110e can tolerate up to 100 more dust and contamination build up when compared with normal optical sensor Alarms Thi...

Страница 28: ...rt phone app For more information on this feature please visit www eielectronics com 5 TESTING MAINTAINING YOUR ALARM INSPECTION TESTING PROCEDURE Check all your Alarms monthly and also after initial...

Страница 29: ...ard sounding in the distance for a further 3 seconds The red light on the first Alarm only will flash about twice a second Check all the other Alarms similarly in turn v Check the functioning of the m...

Страница 30: ...l of the above possible causes of beeps have been ruled out but the beeping has still persisted for over 2 hours with the green light on there may be some other problem with the Alarm The Alarm must b...

Страница 31: ...Alarms are prone to dust and insect ingress which can cause false alarms or failure to alarm The latest design materials and manufacturing techniques have been used in the construction of our Alarms t...

Страница 32: ...7 Alarm Memory After an alarm activation the red indicator light will flash twice 1 second apart every 48 seconds This will continue for the following 24 hours to indicate that the Alarm has previousl...

Страница 33: ...r Return the Alarm see GETTING YOUR ALARM SERVICED section This appliance is only intended for premises having a residential type environment Fire Smoke Heat Alarms are not a substitute for insurance...

Страница 34: ...an from flames 3 Get out as fast as you can Do not stop for packing Have a prearranged meeting place outside for all family members Check everybody is there 4 Call the Fire Brigade immediately on a mo...

Страница 35: ...e is too far away if the fire is on another floor behind a closed door in a chimney in a wall cavity or if the prevailing air draughts carry the smoke heat away Installing Alarms on both sides of clos...

Страница 36: ...Electronics guarantees this Alarm for five years from date of purchase against any defects that are due to faulty materials or workmanship This guarantee only applies to normal conditions of use and...

Страница 37: ...have the red light flashing Using the Memory Feature If an Alarm has been activated the red LED will flash twice 1 second apart every 48 seconds for 24 hours or until the test button is pressed which...

Страница 38: ...e nearest address in this booklet see Getting Your Alarm Serviced section If 2 beeps occurs at the same time as 2 amber light flashes on the cover then one of the sensors may be defective Switch off t...

Страница 39: ...sal will prevent possible harm to the environment or to human health When disposing of this product please separate it from other waste streams to ensure that it can be recycled in an environmentally...

Страница 40: ...bility Pass Tolerance to voltage supply Pass Response delay and temperature resistance Pass Vibration resistance Pass Humidity resistance Pass Corrosion resistance Pass Electrical stability Pass 15 Do...

Отзывы: