4.1 Mounting & Wiring Alarms
1.
Select a location complying with the
advice in previous sections (see pages
8-18).
2.
Disconnect the AC mains supply from
the circuit that is going to be used.
3.
Lift off the wiring cover as shown in
Figure 3
.
The wiring must be connected to the terminal
block on the mounting plate as follows:
L: Live
- connect to the house wires
coloured brown or marked L.
N: Neutral
- connect to the house wires coloured blue or marked N.
IC: Interconnect
- see Section 4.2 & Figure 6 for information on interconnection.
Note:
Wiring must be installed in compliance with local regulations.
Warning:
Mixing the Live and Neutral connections when interconnecting Alarms
will damage all the Alarms - ensure that the same colours are used throughout the
premises for Live, Neutral and Interconnect wires.
We strongly recommend that you check for the following
before connecting the
Alarm
:
• check for Live and Neutral using a two probe tester.