8
5. Ra Upgradeable -
The Ei2110e has modular RF capability when used in
conjunction with the Ei100MRF Ra Module. This feature allows the Ei2110e
to communicate with other RF devices as an alternative to a hard-wired interconnection.
The Ei2110e can function in RF, hard-wired or hybrid systems. For more information
on the added Ra features please visit www.eielectronics.com.
6. AudioLINK -
The Ei2110e is equiped with the AudioLINK feature. This allows for the
download of information such as a record of any alarm incidents / battery status /
chamber contamination levels from the Ei2110e using the AudioLINK smart phone app.
For more information on this feature please visit www.eielectronics.com.
5. TESTING & MAINTAINING YOUR ALARM
INSPECTION & TESTING PROCEDURE
Check
all
your Alarms monthly, and also after initial installation or after re-occupation (e.g.
following a holiday):
(i) Check that the
green mains indicator light
is on. (If it is off check circuit breakers, fuses
and wiring etc.) Check the red light on the cover flashes every 48 seconds.
(ii) Press the
test button
for up to 10 seconds and ensure that the Alarm sounds. This tests
the sensors, electronics and sounder are working. A red light on the cover will flash while
the Alarm is sounding. The Alarm will stop when the button is released. Pressing the test
button simulates the effect of smoke and heat during a real fire and is the best way to ensure
the Alarm is operating correctly.