18
3. REGULAR OR IRREGULAR SINGLE BEEPS:
Check the green mains power light is on. If not, check the fuse, circuit breakers and wiring
connections. If the green light is off, the internal back-up cells will deplete after some months
and will need to be recharged. Reinstate the mains supply to the Alarm and the back-up cells
will automatically recharge. If the mains has been reinstated for a number of hours and the
beeps have not ceased, a fault may exist. Switch off the mains,remove the Alarm - (see
“
ALARM REMOVAL
” section) and return it to the nearest address in this booklet - see
“
GETTING YOUR ALARM SERVICED
”
section.
If 2 beeps occurs at the same time as 2 amber light flashes on the cover, then one of the
sensors may be defective. Switch off the mains, remove the Alarm (see “
ALARM
REMOVAL
” section) and return it to the nearest address given at the end of this leaflet - see
“
GETTING YOUR ALARM SERVICED
” section.
4. INTERCONNECTED ALARMS DO NOT ALL SOUND:
(1) Hold Test/Hush button for 10 seconds after first Alarm has sounded to ensure the
interconnect signal is transmitted to all units.
(2) One or more of the connections may not be correctly connected. We recommend you
consult a qualified electrician.
see Indicator chart in Section 3 for further information on the status of the Alarm