Appendix
EFORT INTELLIGENT EQUIPMENT CO.,LTD
265
1825
0x220000
00
Error of safety
board hand
pressure sign
al
Safety board
hand pressure
signal is
incorrect.
1. After pressing the
reset button on the front
panel of the electric
cabinet, press the hand
press button again, and
observe whether the
ENA light of the safety
board is on;
2. Check whether the
hand-pressed signal
wiring between the teach
pendant and the X9
connector of the safety
board is disconnected or
poorly connected;
3. Replace the safety
board;
4. Restart the electric
cabinet.
1826
0x220000
00
Error of Safet
y board STO
P1
Safety board
STOP1 is
incorrect.
1. Press the reset button
on the front panel of the
electric cabinet and
observe whether the
STOP1 light of the safety
board is on;
2. Check whether the
wiring between the X7
connector of the safety
board and the external
emergency stop terminal
on the front panel of the
electric cabinet is
disconnected or poorly
connected;
3. Replace the safety