Appendix
EFORT INTELLIGENT EQUIPMENT CO.,LTD
263
1821
0x220000
00
Safety board:
Safety door a
larm
Safety door
prompts an
alarm.
1. Check whether the
safety door is opened and
confirm whether there
are workers in the work
area;
2. Check whether the
safety door signal is
normal.
1822
0x220000
00
Safety board:
Safety grating
alarm
Safety grating
prompts an
alarm.
1. Check whether the
safety grating is triggered
and confirm whether
there are workers in the
work area;
2. Check whether the
safety grating signal is
normal.
1823
0x220000
00
Error of safety
board emerg
ency stop sig
nal
Safety board
emergency stop
signal is
incorrect.
1. Please check whether
the emergency stop
button is reset after
pressing;
2. Press the reset button
on the front panel of the
electric cabinet and
observe whether the
EMG and EMGO lights
of the safety board are
on;
3. Check whether the
wiring between the X4
connector of the safety
board and the emergency
stop button on the front
panel of the electric
cabinet is disconnected
or poorly connected;