DBL Operating Instructions / MPC4
Last updated: 03.12.2020
Page 9 of 26
5.2. General notes on operation
Should a parameter be changed by the user, it can be selected with the UP / DOWN
buttons at the device and activated for editing by means of the ENTER button. When a
parameter value flashes, it is able to be edited with the UP / DOWN buttons. When
pressing the ENTER button again the new adjusted value is accepted.
Due to safety reasons some parameters (e.g. changing the operation mode like
AUTOMODE, SUPPLYMODE, and CHARGEMODE etc.) cannot be configured when the
charging computer is in operation (load detection is activated or SUPPLYMODE or
CHARGEMODE). For this purpose the active operation has to be deactivated by selecting
’STOP‘.
5.3. Main Screen
Picture 2 – main screen
-
Screen display ‘START / STOP’ changes depending on the operation mode.
•
Display ‘START‘: DBL is on standby and can activate the load detection circuit
for the displayed operation mode (AUTO, SUPPLY or CHARGEMODE) by
selection of ‘START‘ (pressing the ENTER button). The process will be started
by recognized and valid load.
•
Display ‘STOP‘: Device is in an active supply or charging mode or the load
detection of the charger is activated. With the selection of ‘STOP‘ via ENTER
button the supply or charging mode is ended.
-
Selecting MENU with pushing ENTER the access to the configuration menu will be
visible. Depending on the active configuration or customized terms of delivery the
access to the menu is protected with a PIN code – see chapters 5.4 and 5.5.
Values:
Voltage U [V]
Current I [A]
Status / error message
Operation mode
Access to configuration menu
START/STOP Function
- STOP: Standby
- START: Load detection active or
load/BAT is energized