DBL Operating Instructions / MPC4
Last updated: 03.12.2020
Page 16 of 26
5.5.6. Device Menu
Picture 8 – device menu
Parameter
Options
Figures / range of adjustment
STORAGE
OFF
No temporary saving of the charging process state.
CYCLIC
Every 5 minutes relevant operating parameters such
as operating modus or timer values are saved and
reactivated after mains power returns. [1]
PARAMETER
Default
Factory-made standard settings for the operating
parameters of the charger are activated.
User
When changing the factory settings the display ‘user’
appears.
Note: On the main screen (refer to Picture 1) you
can see ‘*’ in front of the parameter set number.
MAN. START
AUTOSTART
The predefined operating mode starts automatically
after network return during recognition of load or
battery.
MAN. START
The user starts the device manually with the start
button on the main screen (see chapter 5.3).
AUTOSTOP
AUTOSTOP
Safety shutdown is activated for Q
max
or T
max
.
MAN. STOP
ATTENTION - Switching-off at Q
max
/ T
max
limit is
deactivated! End of supply only takes place after
load is disconnected, after choosing the stop
function in the main menu or via external control. [2]