Deutronicstr. 5, D - 84166 Adlkofen, Germany
Tel.: +49 (0) 8707 920-0
Fax: +49 (0) 8707 1004
E-mail: [email protected]
http://www.deutronic.com
DBL Operating Instructions / MPC4
Last updated: 03.12.2020
Page 12 of 26
5.5.3. Supply Menu (parameters for the SUPPLYMODE)
Picture 5 – supply menu
[1] Output voltage [U]:
If the chosen voltage is available on the output depends on both the load
conditions in operation and the choice of the OVP limit (see parameter Umax
in chapter 5.5.6 Device Menu submenu “SAFETY”)
[2] Current limit [I
max
]:
If the configured current maximum I
max
is available on the output
depends on
the (load) condition in the operating status. Note: During SUPPLYMODE the
output current limit can automatically be adjusted/reduced via the dynamic
output power and temperature control.
Parameter
Description
Figures / range of adjustment
U in [V]
Output voltage
[2 ... 17] V (or max. 20 V on type DBL800-14)
The height of the output current should be
selected so that the connected consumers have
sufficient power. [1]
ATTENTION: Too high voltages can cause
damage on the motor vehicle electrical system!
I
max
in [A]
Current limit
Output current
[0 ... I
max
] A
The available maximum value depends on the
power class of the device - see data sheet [2].
ATTENTION: The current limit has to be checked
and if necessary adapted to the connected
equipment (e.g. charging cable and clamps)