Upload/Download Via Alarm Link Software
The
Solution 4+4
control panel can be remotely programmed or controlled via an IBM or
compatible personal computer via the Alarm Link Software (CC816). This facility will allow
you to make alterations to your customers control panel without the need to leave your office,
thus improving customer service and saving you time and money. For country locations where
a control panel may be situated hundreds of kilometres from your office, the Upload/Download
feature is invaluable.
When selecting the control panel type during the setup of a new customer database in the
Alarm Link Software, refer to the table below to select the software version number that
corresponds to the control panel type required.
Control Panels Software Version
Select Panel Type
1.2x
S4_V12
Table 31: Alarm Link Panel Forms
After selecting the correct panel type when adding a new customer in the Alarm Link Software,
the Subscriber ID Number and the Installer Code will need to match that of the control panel
for synchronisation when making connection to the control panel. If these two locations do not
match that of the control panel, the computer and the control panel will not synchronise.
Remote Connect
The remote connect feature allows you to establish a connection through the telephone network
from your IBM or compatible computer to the
Solution 4+4
control panel anywhere in the
country where a telephone line is present. The advantages of this are very obvious and having
this facility will allow you to offer faster service to your clients.
Remote Connect With Customer Control
If you wish to configure the control panel so that a remote connection can only be established
when the client initiates it through the remote codepad, you will need to program the following
information.
"LOCATION 32 - 47" on page 83 will need to have the Callback Telephone Number
programmed and Option 4 in "LOCATION 224" on page 134 will need to be disabled. The
control panel has now been set so that the client has control of when a remote connection can
be established.
To initiate the control panel to dial the remote computer to establish a link, hold the
6
button
down until two beeps are heard on the remote codepad.
Remote Connect Without Callback Verification
Remote connect without callback verification can be handy where you have a need to perform
Upload/Download functions from multiple locations. It should be noted that by using this
feature you are reducing the security of the control panel.
"LOCATION 32 - 47" on page 83 should be cleared and Option 4 in "LOCATION 224" on
page 134 will need to be enabled. The control panel will now allow a connection of the first
call without calling the remote computer back to make contact.
Remote Operations
67
Electronics Design and Manufacturing Pty Limited
ISSUE123.DOC
Содержание Solution 4+4
Страница 1: ...Solution 4 4 Installation Manual ISSUE 1 23...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 13: ...Introduction This section includes the following Introduction Features Quick Start...
Страница 64: ...64 Solution 4 4 Installation Manual ISSUE123 DOC Electronics Design and Manufacturing Pty Limited...
Страница 80: ...80 Solution 4 4 Installation Manual ISSUE123 DOC Electronics Design and Manufacturing Pty Limited...
Страница 88: ...88 Solution 4 4 Installation Manual ISSUE123 DOC Electronics Design and Manufacturing Pty Limited...
Страница 89: ...User Codes This section includes the following Installer Code User Codes User Code Priority...
Страница 154: ...154 Solution 4 4 Installation Manual ISSUE123 DOC Electronics Design and Manufacturing Pty Limited...
Страница 155: ...Appendices This section includes the following Telephone Anti Jamming Test Reports Only When Armed...
Страница 158: ...158 Solution 4 4 Installation Manual ISSUE123 DOC Electronics Design and Manufacturing Pty Limited...
Страница 162: ...162 Solution 4 4 Installation Manual ISSUE123 DOC Electronics Design and Manufacturing Pty Limited...
Страница 163: ...Programming Sheets...
Страница 168: ...168 Solution 4 4 Installation Manual ISSUE123 DOC Electronics Design and Manufacturing Pty Limited...
Страница 169: ...Index...
Страница 174: ......