0
Entry W Day Alarm Resetting
This output combines both Entry Warning and Day Alarm Resetting so that either of
these two events will activate the output.
If the output has been triggered by either Entry Timer 1, Entry Timer 2, or Entry
Guard Timer For STAY Mode, the output will reset once the entry timer has expired
or the system has been disarmed.
If a zone programmed for day alarm has triggered the output, the output will reset
when the zone has resealed. Refer to “LOCATION 101” on page 94 for
programming zones for day alarm.
Day alarm can be turned on and off by holding down the
4
button. Three beeps
indicates that day alarm has been turned on, two beeps indicates that day alarm has
been turned off. Refer to "Hold Down Functions" on page 61 for further
information on day alarm.
0
Day Alarm Resetting
This output will operate when a zone programmed for day alarm has been triggered.
The output will reset when the day alarm zone has resealed. Refer to “LOCATION
101” on page 94 for programming zones for day alarm.
Day alarm can be turned on and off by holding down the
4
button. Three beeps
indicates that day alarm has been turned on, two beeps indicates that day alarm has
been turned off. Refer to "Hold Down Functions" on page 61 for further
information on day alarm.
0
Day Alarm Latching
This output will operate when a zone programmed for day alarm has been triggered.
The output will reset when the
button has been pressed. Refer to
“LOCATION 101” on page 94 for programming zones for day alarm.
Day alarm can be turned on and off by holding down the
4
button. Three beeps
indicates that day alarm has been turned on, two beeps indicates that day alarm has
been turned off. Refer to "Hold Down Functions" on page 61 for further
information on day alarm.
10
Day Alarm Enabled
This output will operate as soon as day alarm has been enabled. The output will
reset when day alarm has been turned off.
Day alarm can be turned on and off by holding down the
4
button. Three beeps
indicates that day alarm has been turned on, two beeps indicates that day alarm has
been turned off. Refer to "Hold Down Functions" on page 61 for further
information on day alarm.
14
AC Fail
This output will operate as soon as the AC mains has failed. The output will reset as
soon as the AC mains has restored. This output will operate regardless of Option 4
in "LOCATION 228" on page 138 being set.
15
Low Battery
This output will operate when a dynamic battery test detects that the battery has
failed or the battery voltage has fallen below 10.5 volts. The dynamic battery test is
performed every four hours from when the system has been powered up or every
time the system has been armed in AWAY Mode or STAY Mode.
This output will reset only after a dynamic battery test reports the backup battery has
restored.
Programmable Outputs
119
Electronics Design and Manufacturing Pty Limited
ISSUE123.DOC
Содержание Solution 4+4
Страница 1: ...Solution 4 4 Installation Manual ISSUE 1 23...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 13: ...Introduction This section includes the following Introduction Features Quick Start...
Страница 64: ...64 Solution 4 4 Installation Manual ISSUE123 DOC Electronics Design and Manufacturing Pty Limited...
Страница 80: ...80 Solution 4 4 Installation Manual ISSUE123 DOC Electronics Design and Manufacturing Pty Limited...
Страница 88: ...88 Solution 4 4 Installation Manual ISSUE123 DOC Electronics Design and Manufacturing Pty Limited...
Страница 89: ...User Codes This section includes the following Installer Code User Codes User Code Priority...
Страница 154: ...154 Solution 4 4 Installation Manual ISSUE123 DOC Electronics Design and Manufacturing Pty Limited...
Страница 155: ...Appendices This section includes the following Telephone Anti Jamming Test Reports Only When Armed...
Страница 158: ...158 Solution 4 4 Installation Manual ISSUE123 DOC Electronics Design and Manufacturing Pty Limited...
Страница 162: ...162 Solution 4 4 Installation Manual ISSUE123 DOC Electronics Design and Manufacturing Pty Limited...
Страница 163: ...Programming Sheets...
Страница 168: ...168 Solution 4 4 Installation Manual ISSUE123 DOC Electronics Design and Manufacturing Pty Limited...
Страница 169: ...Index...
Страница 174: ......