background image

Introduction

This section includes the following;

 

Introduction

 

Features

 

Quick Start

Содержание Solution 4+4

Страница 1: ...Solution 4 4 Installation Manual ISSUE 1 23...

Страница 2: ......

Страница 3: ...This page has been included for you to cut out and insert into the spine of the folder MA400I Solution 4 4 Installation Manual 61 2 9672 1233 ISSUE 1 23...

Страница 4: ......

Страница 5: ...ument trademark names may have been used Rather than put a trademark symbol in every occurrence of a trademark name we state that we are using the names only in an editorial fashion and to the benefit...

Страница 6: ......

Страница 7: ...___________________________29 Disable Factory Default_________________________________________________________________________29 Defaulting The Control Panel __________________________________________...

Страница 8: ...______________________________________________________44 System Functions_________________________________________________________________ 45 System Functions _________________________________________...

Страница 9: ..._______________________________________76 Domestic Dialling Function____________________________________________________________________76 Programming Domestic Reporting ______________________________...

Страница 10: ...1 Zone Options________________________________________________________________________________102 Lockout Siren Lockout Dialler ______________________________________________________________102 Silent...

Страница 11: ...__________________________________________________________________________128 Entry Timer 2________________________________________________________________________________128 Exit Time _______________...

Страница 12: ..._______140 Enable Alarm Memory Reset On Disarm ________________________________________________________140 Optional Equipment______________________________________________________________ 141 Optional...

Страница 13: ...Introduction This section includes the following Introduction Features Quick Start...

Страница 14: ...ry default to final commissioning All system parameters and options are detailed however suitability is left up to the individual Every control panel can be tailored to meet all requirements quickly a...

Страница 15: ...larms STAY Mode and AWAY Mode Operation Entry and Exit Warning Beeper Four Programmable Burglary Zones Four 24 Hour Tamper Zones Zone Lockout Sensor Watch Day Alarm Dynamic Battery Testing Remote Armi...

Страница 16: ...Telephone Number followed by the Secondary Telephone Number and the Subscriber ID Number 7 Set the time for the test reports if required Any other programming changes required may also be made otherwi...

Страница 17: ...owing Programming Programming With The Remote Codepad Programming With The Hand Held Programmer Programming With The Programming Key Programming Option Bits Installer s Programming Commands Disable Fa...

Страница 18: ...ring the data You will repeat this procedure until all the data has been programmed to suit your requirements The factory default settings have been selected for reporting in the Contact ID Format The...

Страница 19: ...button This will step you to the next location and the data in that location will be displayed via the ZONE indicators If you press the button without previously entering a location number the system...

Страница 20: ...ory Example To enter the Installer s Programming Mode enter the followed by the button The factory default Installers Code is 1234 Three beeps will be heard and the hand held programmers display will...

Страница 21: ...ting a programming key and then altering any location would cause a simultaneous update of not only the programming keys data but also the control panels data Therefore you are not able to alter data...

Страница 22: ...segment display from left to right If there is a dash illuminated on the display the corresponding zone is unsealed and if the display is blank the zone is sealed The third or centre display shows the...

Страница 23: ...in the EXT position and that no external key has been plugged onto the hand held programmer 2 Enter the Installer s Programming Mode ie 1234 followed by the button 3 Plug the programming key onto the...

Страница 24: ...o Programming Key Using The Hand Held Programmer 1 Before connecting the hand held programmer to the control panel make sure that the switch on the hand held programmer is in the EXT position and that...

Страница 25: ...ramming Key Memory To Control Panel Using Hand Held Programmer 1 Before connecting the hand held programmer to the control panel make sure that the switch on the hand held programmer is in the EXT pos...

Страница 26: ...The Hand Held Programmer 1 Before connecting the hand held programmer to the control panel make sure that the switch on the hand held programmer is in the EXT position and that no external programmin...

Страница 27: ...ts 0 0 Not Used LOCATION 154 155 Trouble Reports 0 0 Not Used LOCATION 156 159 Codepad Duress 0 0 0 0 Not Used LOCATION 160 163 Codepad Panic 0 0 0 0 Not Used LOCATION 164 167 Access Denied 0 0 0 0 No...

Страница 28: ...ive locations How To Enable Automatic Stepping Of Locations 1 Enter Installer s Programming Mode ie 1234 followed by the button 2 Enter command 966 followed by the button Two beeps will be heard How T...

Страница 29: ...ocation defaulting of the control panel will not operate and the Installer Code MUST be used for further programming of the control panel If the Installer Code is not known the control panel will need...

Страница 30: ...ze relay RL1 on the control panel click once and two beeps will be heard on the remote codepad The control panel will now need to be disarmed by using the default Master Code ie 2580 The control panel...

Страница 31: ...epad CP5 Eight Zone LCD Codepad System Operations Arming The System In AWAY Mode Disarming The System From AWAY Mode Arming The System In STAY Mode Disarming The System From STAY Mode Codepad Duress A...

Страница 32: ...nsealed Indicator Definition On Zone Is Unsealed Off Zone Is Sealed Flashing Fast 0 25 Sec On 0 25 Sec Off Zone Is In Alarm Condition Flashing Very Fast 0 1 Sec On 0 1 Sec Off Tamper Zone Is In Alarm...

Страница 33: ...r Audible Indicators In general the audible indications given out by the codepad are as follows Indicator Definition One Short Beep A Button Has Been Pressed On The Codepad Or End Of Exit Time When Ar...

Страница 34: ...ing Fast 0 25 Sec On 0 25 Sec Off Zone Is In Alarm Condition Flashing Very Fast 0 1 Sec On 0 1 Sec Off Tamper Zone Is In Alarm Condition Flashing Slow 1 Sec On 1 Sec Off Zone Is Manually Isolated Flas...

Страница 35: ...l flash once every 3 seconds FAULT Indicator The FAULT indicator is used to indicate that the system has detected a system fault Refer to Fault Analysis Mode on page 43 for more information Indicator...

Страница 36: ...ns given out by the codepad are as follows Indicator Definition One Short Beep A Button Has Been Pressed On The Codepad Or End Of Exit Time When Armed In STAY Mode Two Short Beeps The System Has Accep...

Страница 37: ...n active part of the system again as soon as it has resealed ie If a window is left open after exit time has expired the window will not be an active part of the system until it has closed Opening the...

Страница 38: ...o Arm The System In STAY Mode 1 Hold down the button until two beeps are heard The STAY indicator will illuminate and exit time will now commence Any zones that have been programmed for STAY Mode will...

Страница 39: ...STAY indicator will extinguish A flashing ZONE indicator represents a previous alarm on that zone Method Two A flashing ZONE indicator represents a previous alarm on that zone If this is the case a v...

Страница 40: ...ed simultaneously This is an audible alarm Refer to Option 4 in LOCATION 227 on page 137 to enable codepad panic to be silent If you wish to disable the reporting of the codepad panic alarm report ref...

Страница 41: ...heard 2 Enter the required to be isolated followed by the button The zone you just selected to be isolated will now begin to flash Repeat Step 2 if more than one zone is required to be isolated until...

Страница 42: ...the button when finished selecting the zones to be isolated Two beeps will be heard The isolated zones will now continue to flash until the system has next been disarmed The system is ready to be arm...

Страница 43: ...steady and the STAY and AWAY indicators will flash in unison with each other The ZONE indicators will indicate the type of system fault Refer to Table 18 Fault Indicators below for the list of differ...

Страница 44: ...ions on page 102 for setting zones to be monitored for sensor watch Horn Speaker Monitor A horn speaker fault will register when the horn speaker becomes disconnected from the control panel This fault...

Страница 45: ...System Functions This section includes the following Installer Code Functions Master Code Functions Hold Down Functions...

Страница 46: ...Master Code To enter the required Installer Code function enter the followed by the required digit and the button These functions can only be carried out when the system is in the disarmed state Func...

Страница 47: ...Two beeps will be heard and the STAY and AWAY indicators will begin to flash in unison with the FAULT indicator One or more zone indicators 1 8 will illuminate indicating the type of fault that has oc...

Страница 48: ...days until the first test report Otherwise the next test report will report as programmed in the repeat interval time How To Set The First Test Report 1 Enter your followed by 2 and the button Three...

Страница 49: ...ne 4 4 System Disarmed Table 21 Event Memory Recall Example Events The event memory playback will report as follows Event No Codepad Indicator Event Description 4 All Indicators Off Except MAINS Syste...

Страница 50: ...button to exit this function Two beeps will be heard and the STAY and AWAY indicators will extinguish 4 Satellite Siren Service Mode If an EDMSAT is connected to Output 1 this function will allow you...

Страница 51: ...one Line Seized 2 Dialling Phone Number 3 Handshake Received 4 Data Is Being Transmitted 5 Kiss Off Received None Telephone Line Released Table 23 Telephone Monitor Mode Indications How To Turn Teleph...

Страница 52: ...ed Master Code function enter the followed by the required digit and the button These functions can only be carried out when the system is in the disarmed state Function Description 0 Reserved 1 Chang...

Страница 53: ...ZONE indicator will illuminate Refer to Table 25 Zone Indicators Showing Relative User Numbers on page 54 3 Enter the digits required for the followed by the button Two beeps will be heard and the ST...

Страница 54: ...extinguish If you wish to delete any further user codes repeat this procedure as many times as required 1 When deleting user codes this function will automatically terminate if a button is not presse...

Страница 55: ...esponding codepad indicators will illuminate 3 After you have entered all the digits of the first telephone number press the button if there is more than one telephone number to be programmed This wil...

Страница 56: ...f the events were as follows Event No Event Description 1 System Armed In AWAY Mode 2 Alarm In Zone 3 3 Alarm In Zone 4 4 System Disarmed Table 27 Event Memory Recall Example Events The event memory p...

Страница 57: ...r followed by 4 and the button Three beeps will be heard and the STAY and AWAY indicators will begin to flash The codepad will beep once every second while the system is in the walk test mode 2 Unseal...

Страница 58: ...cators will begin to flash in unison with the FAULT indicator One or more zone indicators 1 8 will also illuminate indicating the type of fault that has occurred Refer to Fault Descriptions on page 44...

Страница 59: ...If the date and time needs to be set for the 1st January 1997 at 10 30 PM program the date and time as follows 6 0 1 0 1 9 7 2 2 3 0 Turn Day Alarm On and Off This function will allow you to turn day...

Страница 60: ...d the button Two beeps will be heard and all latching outputs will reset 8 Initiate Modem Call This function will force the control panel to dial the callback telephone number programmed in an attempt...

Страница 61: ...LOCATION 230 on page 140 will need to be enabled for this hold down function to operate If an alarm has occurred or entry warning has been triggered a valid user code will need to be used to disarm t...

Страница 62: ...Mode There are various system faults that can be detected by the control panel When any of these are present the FAULT indicator will begin to flash and the codepad will beep once every minute Refer...

Страница 63: ...tinuously will change the tone of the buzzer in the remote codepad There are fifty different tones to choose from between 1500 Hz and 5000 Hz and they are specific to each codepad In a multiple codepa...

Страница 64: ...64 Solution 4 4 Installation Manual ISSUE123 DOC Electronics Design and Manufacturing Pty Limited...

Страница 65: ...Remote Operations This section includes the following Remote Operations Remote Arming Via The Telephone Upload Download Via Alarm Link Software...

Страница 66: ...ouch tone telephone for 3 seconds to arm the system If you hear a number of strange sounding tones when the control panel answers the incoming call this means that the system has been programmed for r...

Страница 67: ...work from your IBM or compatible computer to the Solution 4 4 control panel anywhere in the country where a telephone line is present The advantages of this are very obvious and having this facility w...

Страница 68: ...control panel Secondly the control panel will callback the programmed callback phone number to establish the valid connection The Callback Telephone Number is the phone line that the modem and comput...

Страница 69: ...cludes the following Dialler Reporting Formats Contact ID Format Point ID Codes Event Codes General Reporting Formats Securitel Domestic Reporting Format Domestic Dialling Function Programming Domesti...

Страница 70: ...ualifier Which Gives Specific Event Information 1 New Event Or Opening 3 New Restore Or Closing Event Code Made Up Of 3 Hex Digits Group Number Made Up Of 2 Hex Digits Point ID Number Made Up Of 3 Hex...

Страница 71: ...lure 113 Zone Specific 1 4 Trouble 380 Fixed Sensor Trouble 108 Zone Specific 9 12 Tamper Trouble 383 Fixed Sensor Trouble Tamper 108 Zone Specific 1 4 Bypass 570 Fixed Zone Bypass 108 Table 33 Point...

Страница 72: ...203 Gate Valve Sensor Protection Loop Trouble 122 Silent Alarm 204 Low Water Level 370 Protection Loop 123 Audible Alarm 205 Pump Activated 371 Protection Loop Open Burglary Alarms 206 Pump Failure 3...

Страница 73: ...nsion code Event 3 1 4 1 Universal 3 1 4 1 Expanded 4 2 Alarm SSS S A SSS S A AAA A CH SSSS ACH Trouble SSS S T SSS S T TTT T CH SSSS TCH Bypass SSS S B SSS S B BBB B CH SSSS BCH AC Fail SSS S E SSS S...

Страница 74: ...ry Restore Code 1st Digit E AC Fail Code 1st Digit LBR Low Battery Restore Code 2nd Digit AC AC Fail Code 2nd Digit D Duress Code 1st Digit L Low Battery Code 1st Digit D0 Duress Code 2nd Digit LB Low...

Страница 75: ...167 111 Table 37 Securitel Reporting Messages Zone bypass and zone trouble reports are not transmitted separately They are transmitted as one combined isolate report How To Program and Setup Securite...

Страница 76: ...en tone followed by a unit identification beep The identification beep will allow the customer to verify which control panel made the call if more than one control panel is reporting to the same telep...

Страница 77: ...codepad Refer to Table 26 Zone Indicators For Changing Phone Numbers on page 56 for the indicators and their meanings If there are no telephone numbers programmed a further two beeps will be heard aft...

Страница 78: ...o continue calling your work place or mobile phone etc you may enter the following sequence 1 Enter the followed by 2 and the button Three beeps will be heard and the STAY and AWAY indicators will beg...

Страница 79: ...CATION 052 055 requires a Subscriber ID Number programmed 3 LOCATION 049 requires Option 5 Pager Handshake to be selected 4 LOCATION 050 requires Option 12 Basic Pager Format to be selected Figure 3 B...

Страница 80: ...80 Solution 4 4 Installation Manual ISSUE123 DOC Electronics Design and Manufacturing Pty Limited...

Страница 81: ...s the following Base Station Information Primary Telephone Number Secondary Telephone Number Callback Telephone Number Dialling Format Handshake Tone Transmission Format Transmission Speed Subscriber...

Страница 82: ...ne number Therefore the dialling sequence will be terminated when a zero appears Example To program the telephone number 9672 1055 you would program the following 96721 5500000000 Programming A Four S...

Страница 83: ...station or pager company for the relevant telephone numbers before programming this location Secondary Telephone Number LOCATION 016 031 0000000000000000 Refer to the Primary Telephone Number for pro...

Страница 84: ...ing DTMF Australian Decadic 6 Alternate DTMF Reversed Decadic Table 40 Dialling Formats The alternating sequence is as follows DTMF Decadic DTMF Decadic DTMF Decadic Handshake Tone LOCATION 049 1 This...

Страница 85: ...d Expanded 14 Reserved 7 3 1 Pulsed Universal 15 Reserved 8 3 1 Pulsed Expanded Table 42 Transmission Formats Transmission Speed LOCATION 051 2 This location selects the speed at which data is transmi...

Страница 86: ...Formats If your base station receiver type is not listed above do not despair there are many combinations of formats speeds and handshake tones Try a few combinations and you will more than likely fi...

Страница 87: ...1 Programming the ring count as 15 will enable Answering Machine Bypass in the primary mode When calling the control panel let the phone ring for no more than 4 rings and then hang up If you call aga...

Страница 88: ...88 Solution 4 4 Installation Manual ISSUE123 DOC Electronics Design and Manufacturing Pty Limited...

Страница 89: ...User Codes This section includes the following Installer Code User Codes User Code Priority...

Страница 90: ...y level of each user code is programmed in the last location of each user code 15 15 15 15 0 User Code Priority There are a total of 8 user codes available that can be altered or deleted at any time b...

Страница 91: ...s the user code holder to arm and disarm the system Isolating of zones will only be allowed by using the method Code To Isolate once this priority level has been set Refer to Isolating Zones on page 4...

Страница 92: ...f you require access denied to be silent 2 Shutdown all codepads that are connected to the control panel and lock them out for the time period programmed in LOCATION 220 on page 130 3 Transmit an Acce...

Страница 93: ...tion This section includes the following Day Alarm Mask Day Alarm Operation EOL Resistor Value Zone Programming Zone Defaults Zone Types Zone Options Keyswitch Zone Options Zone Pulse Count Zone Pulse...

Страница 94: ...day alarm zones will activate the sirens and dialler just as non day alarm zones do When day alarm has been activated it will ignore any zone pulse count settings that have been programmed for that zo...

Страница 95: ...ay alarm zones The STAY indicator can be programmed to indicate whether day alarm has been turned on or off When day alarm has been turned on the STAY indicator will flash once every three seconds Mon...

Страница 96: ...ture also increases the security of the system as there are eleven possible EOL resistor values that can be used This makes it extremely difficult for anyone to tamper with the system If split EOL res...

Страница 97: ...stors Using N O Contacts Figure 5 Connections Of Split EOL Resistors Using One N O Contact Figure 6 Connections Of Split EOL Using Two N O Contacts Zone Information 97 Electronics Design and Manufactu...

Страница 98: ...tion Hundreds Digit The hundreds digit of the Contact ID Event Code is programmed into this location This location is also the Alarm Restore code in all other reporting formats Tens Digit The tens dig...

Страница 99: ...on their corrsponding zone indicator on the codepad Eg If the tamper on Zone 1 becomes unsealed the codepad will then display Zone 1 If an alarm occurs on a burglary zone as well as it s parallel tam...

Страница 100: ...ed 12 24 Hour Burglary 5 Reserved 13 24 Hour Fire 6 Instant Isolated In STAY Mode 14 Chime Only 7 Handover Isolated In STAY Mode 15 Zone Not Used Table 49 Zone Types Instant Zone An Instant zone will...

Страница 101: ...options such as momentary toggle etc User code number 32 will be reported when arming and disarming using this method of operation 24 Hour Burglary Zone A 24 Hour Burglary zone is always ready to trig...

Страница 102: ...Programming a 3 ie 1 2 3 will lockout both the sirens and dialler Restore signals will be transmitted when the system has been disarmed The Solution 4 4 control panel performs lockout different to mos...

Страница 103: ...mines how many 24 hour periods a zone may remain continuously sealed before it registers as a sensor watch fault The number of hours required to fulfil these 24 hour periods is only calculated while t...

Страница 104: ...isarming the system will not be permitted via the keyswitch zone if this option has been selected Latching Disarm From AWAY Mode Or STAY Mode If this option has been selected the system will disarm fr...

Страница 105: ...his option has been selected the system will arm or disarm in STAY Mode when using the momentary keyswitch input Arming the system in AWAY Mode will not be permitted via the keyswitch zone if this opt...

Страница 106: ...zones 24 Hour zones may handover pulses to other zones Zone Pulse Count Time Zone pulse count time is the time frame or period over which the programmed number of pulses must register before an alarm...

Страница 107: ...This section includes the following Zone Bypass Reports Zone Trouble Reports Codepad Duress Report Codepad Panic Report Access Denied AC Fail Report Low Battery Report Sensor Watch Time Open Close Re...

Страница 108: ...sion digit in 4 2 Formats It has no effect on Contact ID Format as a zone bypass will always be reported on event code 570 If Zone Bypass reports are not required program LOCATION 152 153 with a zero...

Страница 109: ...tton is added to the end of any valid user code being used to disarm the system This alarm will always be silent A duress alarm can be triggered during exit time ie If the system has been armed and th...

Страница 110: ...ntact ID Event Code 120 will be transmitted to the base station receiver when either the two outside buttons 1 and 3 or and are pressed simultaneously This is an audible alarm Refer to LOCATION 227 on...

Страница 111: ...Access Denied report Contact ID Event Code 421 will be transmitted to the base station receiver when the number of incorrect code attempts equals the number programmed in LOCATION 102 on page 92 This...

Страница 112: ...174 Contact ID Event Code Units Digit Or Channel Location For All Other Formats 175 Dialler Channel Table 60 System Status Low Battery Report Locations A Battery Test Failure report Contact ID Event...

Страница 113: ...istering as a fault If a Sensor Watch report is not required program LOCATION 176 179 with a zero Open Close Reports LOCATION 180 181 89 Location Description 180 Opening Report Code 181 Closing Report...

Страница 114: ...o test the dialling and reporting functions of the control panel Test reports will not report if the Subscriber ID Number is 0000 When programming test reports the control panel needs to know the hour...

Страница 115: ...utputs This section includes the following Programmable Outputs Output Defaults Redirecting Outputs To The Codepad Buzzer Output Event Types Output Polarity Timing Of Outputs Pulsing Polarities One Sh...

Страница 116: ...etermines whether the output remains operating for the duration of the event pulses for the duration operates once only one shot or latches on How Long To Operate For Is determined by a time base and...

Страница 117: ...iver The output will reset when the first Kiss Off is received This output event type is not applicable for domestic reporting To redirect the above output event type to operate the codepad buzzer pro...

Страница 118: ...t will operate when the system has been armed in AWAY Mode The output will reset when the system is disarmed 06 Exit Warning With All Zones Sealed Or Entry Warning This output will operate during exit...

Страница 119: ...grammed for day alarm has been triggered The output will reset when the button has been pressed Refer to LOCATION 101 on page 94 for programming zones for day alarm Day alarm can be turned on and off...

Страница 120: ...multaneously This output will reset once a valid user code has been entered at the remote codepad 1 Codepad Duress Alarm This output will operate when a duress alarm has been activated by adding a 9 t...

Страница 121: ...tors It is conceptually very similar to zone pulse count as used in some motion detectors Basically a fire zone is allotted a pulse count of 3 pulses over a period of 3 minutes If the smoke detector t...

Страница 122: ...operate when an incoming call has been detected by the control panel The output will reset when the ringing has stopped or when the call has been answered 35 Mimic Zone 1 3 Mimic Tamper Zone 1 36 Mimi...

Страница 123: ...e event occurs The output will switch back to open circuit when the event has restored Time parameters vary the On time of the pulse Normally Open One Shot Low This one shot polarity is normally open...

Страница 124: ...ent occurs The output will switch back to zero volts when the time parameter has expired This one shot time setting will always run its full duration and cannot be manually reset Normally Low One Shot...

Страница 125: ...reater accuracy use 60 seconds for 1 minute intervals and use 60 minutes for one hour intervals Pulsing Polarities When calculating pulsing polarities both the On and Off times need to be programmed T...

Страница 126: ...Time Base Multiplier The On time is calculated by multiplying the time base setting 1 second by the multiplier value 05 ie 1 x 05 5 seconds On Time Increments Tolerance 200 ms 19 8 Sec s 200 ms 200 m...

Страница 127: ...ers This section includes the following Entry Timer 1 Entry Timer 2 Exit Time Entry Guard Timer For STAY Mode Sensor Watch Time Codepad Lockout Time Siren Run Time Siren Sound Rate Swinger Shutdown Co...

Страница 128: ...ould give you the total time of 18 seconds ie 2 16 seconds 18 seconds Entry Time The Solution 4 4 control panel has two separate entry timers Entry time can be programmed between 0 and 255 seconds in...

Страница 129: ...ng delay zones will have the entry delay as programmed in LOCATION 216 217 ie The delay time programmed for a delay zone will be overridden by the entry guard timer If the entry guard timer has been p...

Страница 130: ...iption 221 Increments Of 1 Minute 0 15 Table 75 Siren Run Time Locations The siren run time determines how long the horn speaker will activate during an alarm condition The siren run time can be progr...

Страница 131: ...such as codepad panic access denied and any other system alarms will not effect the swinger shutdown count While the sirens are operating the counter for the sirens is only incremented by the first z...

Страница 132: ...d to be reset Setting The Date and Time The Master Code holder is allowed to set the date and time as follows How To Set The New Date and Time 1 Enter your followed by 6 and the button Three beeps wil...

Страница 133: ...Options Bits This section includes the following Dialler Options 1 Dialler Options 2 System Options 1 System Options 2 System Options 3 Consumer Options 1 Consumer Options 2...

Страница 134: ...ing a touch tone telephone by pressing the button on the phone Refer to Remote Arming Via The Telephone on page 66 for more information Forced arming is automatically assumed when this feature is bein...

Страница 135: ...other alarm condition If the system is disarmed when an alarm occurs only a closing report will be transmitted when the system is next armed Reserved Send Open Close Reports When In STAY Mode If open...

Страница 136: ...will detect when the horn speaker has been disconnected from the speaker terminals The FAULT indicator will illuminate when the horn speaker has been disconnected and will extinguish when the horn spe...

Страница 137: ...ilent If this option has been selected a codepad panic alarm will not operate the horn speaker the bell or the strobe outputs If this option is not selected all three outputs will operate after a code...

Страница 138: ...s has failed refer to Output Event Type AC Fail on page 119 Enable Zone Pulse Count Handover If this option has been selected any zone pulse count readings will handover and accumulate to any zone tha...

Страница 139: ...Strobe In STAY Mode This option will need to be selected if audible alarms are required when the system has been armed in STAY Mode Enable Answering Machine Bypass Only When Armed This option needs to...

Страница 140: ...ation Enable Single Button Disarming From STAY Mode This option will only operate when Option 2 in this location has also been selected This option will allow hold down functions for disarming from ST...

Страница 141: ...Codepad CP508 CP5 Eight Zone LCD Codepad CP508L Night Arm Station CP105 Phone Controller CC911 Hand Held Dialler Tester DD901 Cellular Diallers PS100 Power Supply Module PS100 TF008 Plug Pack TF008 S...

Страница 142: ...e programming key is a unique device that will store all programming information programmed in your control panel once copied to the programming key The programming key can hold all your common config...

Страница 143: ...up inside the casing The TF008 plug pack incorporates a three wire flying lead that enables a mains earth connection to be made between the equipment and the plug pack This connection may be required...

Страница 144: ...board Refer to Option 8 in LOCATION 226 on page 136 for more information As you can see the radio key keyswitch interface allows you the flexibility to perform quite a number of functions cheaply and...

Страница 145: ...Figure 8 Radio Key Keyswitch Interface CC813 Connection Diagram Optional Equipment 145 Electronics Design and Manufacturing Pty Limited ISSUE123 DOC...

Страница 146: ...Figure 9 Radio Key Keyswitch Interface CC813 Connection Diagram 146 Solution 4 4 Installation Manual ISSUE123 DOC Electronics Design and Manufacturing Pty Limited...

Страница 147: ...minals and Descriptions This section includes the following Terminal Definitions and Descriptions Glossary Of Terms Solution 4 4 Wiring Diagram Solution 4 4 Component Overlay Telecom Connection Diagra...

Страница 148: ...king a maximum of 400 mA Output 1 is defaulted to operate a horn speaker The outputs are protected by EDM s unique Integrated Protection System IPS This makes them extremely tolerant to abuse or incor...

Страница 149: ...mmon forms of detection devices are passive infrared smoke photo electric beams reed switches and vibration sensors Dialler Is a device that is used for communicating to a monitoring station mobile ph...

Страница 150: ...If a zone is sealed the detection devices are not violated and the zone indicator will be extinguished ie a reed switch is closed or a detector is on stand by waiting for an intrusion Sensor Watch Sen...

Страница 151: ...Solution 4 4 Wiring Diagram Figure 10 Solution 4 4 Wiring Diagram Terminals and Descriptions 151 Electronics Design and Manufacturing Pty Limited ISSUE123 DOC...

Страница 152: ...Solution 4 4 Component Overlay Figure 11 Solution 4 4 Component Overlay 152 Solution 4 4 Installation Manual ISSUE123 DOC Electronics Design and Manufacturing Pty Limited...

Страница 153: ...Telecom Connection Diagrams Figure 12 Telecom Connection Diagrams For Solution 4 4 Terminals and Descriptions 153 Electronics Design and Manufacturing Pty Limited ISSUE123 DOC...

Страница 154: ...154 Solution 4 4 Installation Manual ISSUE123 DOC Electronics Design and Manufacturing Pty Limited...

Страница 155: ...Appendices This section includes the following Telephone Anti Jamming Test Reports Only When Armed...

Страница 156: ...anel With this simple method of hanging up for ninety seconds we have not only delayed the alarm signal for this time but also the time taken for the original failed call attempts which could easily t...

Страница 157: ...est report will be transmitted at the programmed time thus verifying the operation of the dialler At first glance this may not seem to be a big deal but lets do a few sums and you will see just where...

Страница 158: ...158 Solution 4 4 Installation Manual ISSUE123 DOC Electronics Design and Manufacturing Pty Limited...

Страница 159: ...Specifications This section includes the following Warranty Statement Specifications Software Version Number Advice To Users New Zealand Telepermit Notes...

Страница 160: ...out of abuse alteration or improper application of the equipment Specifications Temperature Range 0 45 Degrees Celsius Humidity 10 95 Power Source TF008 Plug Pack 240 Volt 18 Volt AC 1 3 Amp Stand By...

Страница 161: ...ment shall not be used in any manner that could constitute a nuisance to other Telecom customers Immediately disconnect this equipment should it become physically damaged and arrange for its disposal...

Страница 162: ...162 Solution 4 4 Installation Manual ISSUE123 DOC Electronics Design and Manufacturing Pty Limited...

Страница 163: ...Programming Sheets...

Страница 164: ...0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 Australian DTMF 4 International DTMF 2 Australian Decadic 5 Reversed Decadic 3 Alternate DTMF Decadic AUST 6 Alter...

Страница 165: ...one Pulse Count Time Zone pulse count time is the time frame or period over which the number of pulses must register Zone Descriptions Use this table as a reference to indicate what each zone is conne...

Страница 166: ...Location 182 Actual Hour Of The Day Tens Digit Location 183 Actual Hour Of The Day Units Digit Location 184 Repeat Interval In Days Location 185 Expansion Code For 4 2 Format Location 186 191 Location...

Страница 167: ...When In STAY Mode 8 Delay Siren Until Transmission Complete 0 1 1 Enable Forced Arming 2 Enable EDM Smart Lockout 4 Enable Monitoring Of Horn Speaker 8 Enable Horn Speaker Beeps For Remote Control Ope...

Страница 168: ...168 Solution 4 4 Installation Manual ISSUE123 DOC Electronics Design and Manufacturing Pty Limited...

Страница 169: ...Index...

Страница 170: ...rom Programming Key To Control Panel 25 Command 964 Erase Programming Key 26 Command 965 Set Up Domestic Dialling 27 Command 966 Enable Disable Automatic Stepping 28 Command 999 Display Software Versi...

Страница 171: ...Call 50 Installer Code Function Satellite Siren Service Mode 50 Installer Code Function Send Test Report 51 Installer Code Function Set Number Of Days Until First Test Report 48 Installer Code Functio...

Страница 172: ...hot Open With Reset 124 Output Polarity Normally Low One Shot Open With Retrigger 124 Output Polarity Normally Low Pulsing Open 124 Output Polarity Normally Open Going Low 123 Output Polarity Normally...

Страница 173: ...e Reports 108 Turn Day Alarm On and Off 59 Turn Day Alarm On Off 62 95 Turning Outputs On Off 58 U Unsealed 150 Upload Download Via Alarm Link 67 User Code 150 User Code Priority 91 User Codes 90 W Wa...

Страница 174: ......

Отзывы: