Sensor Watch Report
LOCATION 176 - 179
3071
Location
Description
176
Contact ID Event Code – Hundreds Digit
177
Contact ID Event Code – Tens Digit
Or Alarm Or Expansion Digit In 4+2 Format
178
Contact ID Event Code – Units Digit
Or Channel Location For All Other Formats
179
Dialler Channel
Table 61: System Status – Low Battery Report Locations
A Self Test Failure report (Contact ID Event Code 307) will be reported to the base station
receiver when a zone has not been triggered during the sensor watch time. This report will
continue to be transmitted (according to the frequency of the sensor watch time) until the fault
has been rectified. To clear the fault and stop any further reporting, the zone that has registered
the fault must be unsealed and resealed again. Refer to “LOCATION 218 - 219” on page 129
for setting the number of days a zone may remain sealed before registering as a fault.
If a "Sensor Watch" report is not required, program "LOCATION 176 - 179" with a zero.
Open/Close Reports
LOCATION 180 - 181
89
Location
Description
180
Opening Report Code
181
Closing Report Code
Table 62: Open/Close Reporting Locations
An "Opening" report (Contact ID Event Code 401) will be transmitted to the base station
receiver when the system has been disarmed from AWAY Mode. A "Closing" report (Contact
ID Event Code 401) is transmitted at the end of exit time when the system has been armed in
AWAY Mode.
If an expanded format has been selected, this code will be used as the expansion code and the
user number that armed or disarmed the system will follow in the same transmission.
Refer to Option 4 in "LOCATION 225" on page 135 for programming "Open/Close" reports in
STAY Mode. To program "Open/Close" reports only after a previous alarm, refer to Option 1
in "LOCATION 225" on page 135.
If you do not require "Open/Close" reports, program "LOCATION 180 - 181" with zero.
System Reporting Information
113
Electronics Design and Manufacturing Pty Limited
ISSUE123.DOC
Содержание Solution 4+4
Страница 1: ...Solution 4 4 Installation Manual ISSUE 1 23...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 13: ...Introduction This section includes the following Introduction Features Quick Start...
Страница 64: ...64 Solution 4 4 Installation Manual ISSUE123 DOC Electronics Design and Manufacturing Pty Limited...
Страница 80: ...80 Solution 4 4 Installation Manual ISSUE123 DOC Electronics Design and Manufacturing Pty Limited...
Страница 88: ...88 Solution 4 4 Installation Manual ISSUE123 DOC Electronics Design and Manufacturing Pty Limited...
Страница 89: ...User Codes This section includes the following Installer Code User Codes User Code Priority...
Страница 154: ...154 Solution 4 4 Installation Manual ISSUE123 DOC Electronics Design and Manufacturing Pty Limited...
Страница 155: ...Appendices This section includes the following Telephone Anti Jamming Test Reports Only When Armed...
Страница 158: ...158 Solution 4 4 Installation Manual ISSUE123 DOC Electronics Design and Manufacturing Pty Limited...
Страница 162: ...162 Solution 4 4 Installation Manual ISSUE123 DOC Electronics Design and Manufacturing Pty Limited...
Страница 163: ...Programming Sheets...
Страница 168: ...168 Solution 4 4 Installation Manual ISSUE123 DOC Electronics Design and Manufacturing Pty Limited...
Страница 169: ...Index...
Страница 174: ......