21
Silent Alarm
This output will operate whenever a zone programmed as silent alarm has triggered.
The output will reset when the siren run time expires, an audible alarm has triggered,
or a valid user code has been entered. Refer to “Zone Options” on page 102 for
more information on programming zones to be silent.
22
Alarm When In STAY Mode
This output will operate whenever an audible or silent zone alarm has triggered
when the system has been armed in STAY Mode. The output will reset when the
system has been disarmed.
23
Alarm When In AWAY Mode
This output will operate whenever an audible or silent zone alarm has triggered
when the system has been armed in AWAY Mode. The output will reset when the
system has been disarmed.
25
Fire Alarm Resetting
This output will operate when a 24 hour fire zone is triggered. The output will reset
once a valid user code has been entered or when siren run time expires.
26
Fire Alarm Latching
This output will operate when a 24 hour fire zone has triggered and will reset when
the system has been armed or disarmed.
27
Fire Alarm Verification
This feature is used on some commercial fire control panels to reduce false alarms
on smoke detectors. It is conceptually very similar to zone pulse count as used in
some motion detectors. Basically, a fire zone is allotted a pulse count of 3 pulses
over a period of 3 minutes.
If the smoke detector trips, the voltage to the smoke detector is disconnected for 15
seconds and then reapplied. No alarm has registered.
If within 3 minutes of the first trigger the unit triggers again, no alarm will be
registered and the voltage to the smoke detector will again be disconnected for 15
seconds and then reapplied.
If a third trigger is detected within 3 minutes of the first trigger, (ie. 3 pulses in 3
minutes) a fire alarm will be registered. Power to the smoke detector will be
maintained to facilitate unit identification via the detector memory.
This output should be connected to the negative side of any fire/smoke detector. To
configure an output for this feature, use the following settings.
EVENT TYPE = 2,7
POLARITY = 10
TIMEBASE = 2
MULTIPLIER = 15
The zone that the fire/smoke detector is connected to should be programmed as
follows:
ZONE TYPE = 13
OPTION = 0
ZONE PULSE COUNT = 3
ZONE TIME = 15
28
Remote Control 1
29
Remote Control 2
2
Remote Control 3
These outputs can be remotely activated (Turned "On" or "Off") via the Alarm Link
Software - Refer to your Alarm Link Instruction Manual for further information.
Programmable Outputs
121
Electronics Design and Manufacturing Pty Limited
ISSUE123.DOC
Содержание Solution 4+4
Страница 1: ...Solution 4 4 Installation Manual ISSUE 1 23...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 13: ...Introduction This section includes the following Introduction Features Quick Start...
Страница 64: ...64 Solution 4 4 Installation Manual ISSUE123 DOC Electronics Design and Manufacturing Pty Limited...
Страница 80: ...80 Solution 4 4 Installation Manual ISSUE123 DOC Electronics Design and Manufacturing Pty Limited...
Страница 88: ...88 Solution 4 4 Installation Manual ISSUE123 DOC Electronics Design and Manufacturing Pty Limited...
Страница 89: ...User Codes This section includes the following Installer Code User Codes User Code Priority...
Страница 154: ...154 Solution 4 4 Installation Manual ISSUE123 DOC Electronics Design and Manufacturing Pty Limited...
Страница 155: ...Appendices This section includes the following Telephone Anti Jamming Test Reports Only When Armed...
Страница 158: ...158 Solution 4 4 Installation Manual ISSUE123 DOC Electronics Design and Manufacturing Pty Limited...
Страница 162: ...162 Solution 4 4 Installation Manual ISSUE123 DOC Electronics Design and Manufacturing Pty Limited...
Страница 163: ...Programming Sheets...
Страница 168: ...168 Solution 4 4 Installation Manual ISSUE123 DOC Electronics Design and Manufacturing Pty Limited...
Страница 169: ...Index...
Страница 174: ......