123
SPECIFICATIONS
3. Parameter address map
3-1. PR-80 (Model ID = 00H 00H 05H)
*
The address with “#” the data is transmitted by dividing to 2 byte (higher 4 bits and lower 4 bits).
Ex. When the unit transmit “BCH”, “0BH” is transmitted for first transmitting, and next, “0CH” is transmitted.
3-1-1. Clip Control Preference Area
*
Note, 3-1-1
The corresponding of the range of the playback speed control and the system exclusive setting is follows:
Start Address
Description
00H 00H 00H
System Common Preference Area (Reserved Area)
01H 00H 00H
Clip Control Preference Area (See 3-1-1)
02H 00H 00H
Color Control Preference Area (See 3-1-2)
03H 00H 00H
Reserved Area
11H 00H 00H
System Parameter Area (See 3-1-3)
12H 00H 00H
Clip Control Parameter Area (See 3-1-4)
13H 00H 00H
Color Control Parameter Area (Reserved Area)
4H 00H 00H
Reserved Area
Address
Parameter Name
Sys.Ex. Value
Meaning of Value
01H 00H 00H
Clip Control Rx MIDI Ch.
00H - 10H
1 - 16 Ch., OFF
01H 00H 01H
Note Mode
00H - 02H
OFF, 49 Keys, Assignable
01H 00H 02H
Velocity Curve Type
00H - 08H
Linear, Exp. Shallow, Exp. Deep, Log. Shallow, Log Deep, Tangent,
ArcTangent, 4 Steps, OFF
01H 00H 03H
Playback Speed Control Range
See Note.3-1-1
See Note.3-1-1
01H 00H 04H
Assignable Note Mode : LowerKey
00H - 7FH
Note Number
01H 00H 05H
Assignable Note Mode : UpperKey
00H - 7FH
Note Number
#01H 10H 00H
Playback Speed Control Assignment
01H-05H, 07H-1FH, 40H-5FH, D0H, E0H, FFH
Control Change, Channel Press, Pitch Bend, OFF
#01H 10H 02H
Transition Time Control Assignment
01H-05H, 07H-1FH, 40H-5FH, D0H, E0H, FFH
Control Change, Channel Press, Pitch Bend, OFF
#01H 10H 04H
Audio Level Control Assignment
01H-05H, 07H-1FH, 40H-5FH, D0H, E0H, FFH
Control Change, Channel Press, Pitch Bend, OFF
#01H 10H 06H
T Bar Control Assignment
01H-05H, 07H-1FH, 40H-5FH, D0H, E0H, FFH
Control Change, Channel Press, Pitch Bend, OFF
#01H 10H 08H
Dual Stream Control Assignment
01H-05H, 07H-1FH, 40H-5FH, D0H, E0H, FFH
Control Change, Channel Press, Pitch Bend, OFF
#01H 10H 0AH
Time Trip X Assignment
01H-05H, 07H-1FH, 40H-5FH, D0H, E0H, FFH
Control Change, Channel Press, Pitch Bend, OFF
#01H 10H 0CH
Time Trip Y Assignment
01H-05H, 07H-1FH, 40H-5FH, D0H, E0H, FFH
Control Change, Channel Press, Pitch Bend, OFF
#01H 10H 0EH
Transition Type Control Assignment
01H-05H, 07H-1FH, 40H-5FH, D0H, E0H, FFH
Control Change, Channel Press, Pitch Bend, OFF
#01H 10H 10H
Mix Mode Control Assignment
01H-05H, 07H-1FH, 40H-5FH, D0H, E0H, FFH
Control Change, Channel Press, Pitch Bend, OFF
#10H 10H 12H
Luminance Key Level Control Assignment
01H-05H, 07H-1FH, 40H-5FH, D0H, E0H, FFH
Control Change, Channel Press, Pitch Bend, OFF
#10H 10H 14H
Mask Control Assignment
01H-05H, 07H-1FH, 40H-5FH, D0H, E0H, FFH
Control Change, Channel Press, Pitch Bend, OFF
Sys.Ex. Value Speed Range
Min Center
Max
00H
0.0
1.0 2.0
01H
0.5
1.0 2.0
02H
0.0
1.0 4.0
03H
0.5
1.0 4.0
04H
0.0
1.0 8.0
05H
0.5
1.0 8.0
06H
0.0
1.0
16.0
07H
0.5
1.0
16.0
08H
0.0
1.0
32.0
09H
0.5
1.0
32.0
0AH - 13H
Reserved
14H
0.0
2.0
4.0
15H
0.0
4.0
8.0
16H
0.0
8.0
16.0
17H
0.0 16.0
32.0
18H - 1DH
Reserved
1EH
-2.0
1.0 4.0
1FH
-6.0
1.0 8.0
PR-80_e.book 123 ページ 2005年1月6日 木曜日 午後9時22分