122
SPECIFICATIONS
●
Program Change
Status
Second
CnH
ppH
pp=Program number: 00H - 1FH (prog.1 - prog.32)j
*
Only transmit when the AR control, V-4, or Presenter control is on.
*
The transmit MIDI channel number for the AR control is the channel number one higher
than the number that is set using "AR control." The transmit MIDI channel number for
the Presenter control is the channel number one higher than the number that is set using
"AR control." The transmit MIDI channel number for the V-4 control is the channel
number two higher than the number that is set using "AR control." (When the channel
number exceeds 16, it rolls over to 1.)
*
When the V-4 control or Presenter control is on, see the item of Bank Select.
*
When the AR control is on, see the item of Note On.
■
Channel Mode Message
●
All Note Off
Status
Second
Third
BnH
7BH
00H
*
Only transmit when the Presenter control is on.
*
The transmit channel number is the channel number that is added 2 to the number that is
set in “AR control”. (When the channel number is more than 16, the channel number is
set from 1.)
*
Stops video-clip playback in the Presenter. The "Keep this clip running" setting is
ignored.
■
System Exclusive Message
Status
data
Status
F0H
iiH,ddH,...,eeH
F7H
F0H: Status of the system exclusive message
ii = ID number: Manufacturer number (ID number for the System Exclusive message
identifying the manufacturer). Roland's manufacturer ID number is 41H. The ID numbers
7EH and 7FH are used as extensions to the MIDI standard as the universal non-realtime
message (7EH) and the universal realtime message (7FH).
dd,...,ee = Data: 00H - 7FH (0 - 127)
F7H: EOX (End Of Exclusive)
●
Data set 1 (DT1)
This is the message that transmits the actual data. It is used when you want to set the unit
by transmitting data.
Status
data
Status
F0H
41H, dev, 00H,
F7H
51H, 12H, aaH,
bbH, ccH, ddH,
..., eeH, sum
Explanation of the byte
F0H:
Exclusive status
41H:
ID number (Roland)
dev:
Device ID (dev: 00H – 1FH, 7FH, default setting is 7FH. 7FH is Broadcast.)
00H:
Model ID higher byte (V-LINK message)
51H:
Model ID lower byte (V-LINK message)
aaH:
Address higher byte
bbH:
Address
ccH:
Address
ddH:
Data: The main body of the transmitted data. More than one byte data is
transmitted in order of address.
eeH:
Data
sum:
Checksum
F7H:
EOX (End Of Exclusive)
*
For details of the setting of the address, size or checksum, see
*
Transmitted only when the V-4 or Presenter control is on.
PR-80_e.book 122 ページ 2005年1月6日 木曜日 午後9時22分