92
Scout 320 REV 3:2018
※
Check for correct sensor placement.
※
Check if
S04
Measurement Sensor
was blocked by any
unidentified objects.
※
Check
S04 Measurement Sensor
for loose or damaged wiring
※
Check for correct sensor placement.
※
Check the setting value of
S04
or
Q04 Measurement Sensor.
※
Check whether to have the foreign matter to catch.
※
Check for material in magazine.
※
Check for material position when pre feeding. Adjust as
required.
※
Check for bar in channel
※
Check magazine setting size to allow for material transfer to the
channel.
※
Check air pressure.
※
Check for correct sensor placement.
※
Check
LS06 Pusher Extraction switch
for loose or damaged
wiring
※
Check air pressure.
※
Check for correct sensor placement.
※
Check
LS05 Pusher Introduction Switch
for loose or
damaged wiring
Check for proper engagement to carriage.
※
Change proper length of material.
※
Check the setting value of
P11
.
※
Check the setting value of
P10
.
※
Check the alarm No. on
LCD
display of servo whether it is
abnormal. If yes, contact Edge Technologies for further
troubleshooting assistance.