SPECIAL FEATURES
Use these features to change the following operations:
=
Efficiency mode
=
Maximum days between recharges
=
Auxiliary control
(described on Page 20)
=
Chemical feed volume*
(described on Page 20)
=
Chemical feed timer*
(described on Page 20)
=
97% feature
=
Service reminder
(described on Page 21)
To display one these screens:
1
. From any of the rolling status screens, press the
SELECT (
¡
) button to display the
Main menu
.
2
. Press the DOWN (
6
) button to scroll through the
menu options until
Advanced settings
is highlighted
(See Figure 72).
FIG. 73
4
. Press the DOWN (
6
) button to scroll through the
menu options until
Special features
is highlighted.
5
. Press the SELECT (
¡
) button to display the Special
features menu (See Figure 74).
FIG. 72
3
. Press the SELECT (
¡
) button to display the
Advanced settings menu (See Figure 73).
FIG. 74
6
. Press the DOWN (
6
) button to scroll through the
menu options until the desired option is highlighted
(See list at the top of this column).
7
. Press the SELECT (
¡
) button to display the desired
information screen (See Figures 75-77).
8
.
See the right column on this page for specific
instructions on each cycle time screen.
9
. Press the SELECT (
¡
) button. The display will go
back to the Special features menu (Figure 74).
10
. Press the LEFT (
3
) button three times to return to
the rolling status screens.
*
Only displayed if Auxiliary control is set to Chemical feed.
FIG. 75
FIG. 76
FIG. 77
8a
.
Efficiency mode
: If the desired efficiency
mode already has a black dot next to it (See
Figure 75), go to Step 9. Otherwise, press the
DOWN (
6
) or UP (
5
) buttons to scroll to the
desired efficiency mode, then press SELECT
(
¡
) to choose it.
=
Salt efficient
limits available salt doses to
maintain 4000 grains/lb. of salt efficiency.
Units may recharge more frequently.
=
Auto adjusting
is the default. It automati-
cally adjusts salt doses to target a 3-4 day
interval between recharges. Recommended.
=
High capacity
is for applications where very
low “bleed” (less than 1.5 ppm) of hardness
can be tolerated. Such applications include
water for boilers. This setting will consume
higher quantities of salt.
8b
.
Maximum days between recharges
: Press
the UP (
5
) or DOWN (
6
) buttons to change
the number of days (See Figure 76). The fea-
ture can be set from 1 to 15 days. Setting the
number of days below 1 turns the feature off
and defaults to automatic control of recharging.
8c
.
97% feature
: If the desired option already has
a black dot next to it (See Figure 77, go to
Step 9. Otherwise, press the DOWN (
6
) or
UP (
5
) buttons to scroll to the other option,
then press SELECT (
¡
) to choose it. If this
feature is On, the conditioner/refiner will auto-
matically recharge when 97% of capacity is
used, at any time of day. Default is Off.
ECOWATER
S Y S T E M S
Conditioner/Refiner Operation